1.17 Message Features
132
Feature Guide
2)
SLT setting
In this example:
a)
To send an SMS message to the SLT connected to extension jack 01, enter "3847001" as the 
destination.
b)
To send an SMS message to the SLT connected to extension jack 02, enter "3847002" as the 
destination.
c)
To send an SMS message to the SLT connected to extension jack 03, enter "3847003" as the 
destination.
Conditions
Hardware Requirement: An optional Caller ID card.
The PBX relays text messages from the SMS centre to SMS-enabled SLTs, and vice versa. 
To receive SMS information, you must subscribe to the telephone company's Caller ID service and 
enable Caller ID for the appropriate outside (CO) lines through system programming (
Caller ID 
[900]).
Each SMS-enabled SLT must be programmed to receive Caller ID information through system 
programming (
SLT Caller ID [628]).
If an SLT user sets the Automatic Callback Busy feature by dialling "6" because the selected line is busy 
when he or she tries to send a text message, the SLT will ring when the line becomes idle. To send the 
text message, the user must answer the callback ring, go on-hook, and then make an SMS centre call 
again. 
When a call is received on one of the outside (CO) lines preprogrammed in an SMS Routing Table, the 
destination SLT may ring one time.
If a user wants to receive SMS messages on an SLT, it is recommended to not connect a proprietary 
telephone (PT) in parallel. If the PT user answers the call, the SMS message will not be received.
When an SMS centre call is received at an SLT that has set the Call Forwarding (FWD) feature, the 
FWD feature will not function and the SMS message is received by that SLT.
When an SLT user makes an SMS centre call, in some cases the duration of the call may not be verified 
with SMDR (
1.20.1 Station Message Detail Recording (SMDR)), because it takes very little time to 
send SMS messages. To verify the duration of these calls, it is recommended to set the start timer of 
call duration to "5 s" or "Instantly" through system programming (
Call Duration Counter Start [204]).
When a user on an SLT that is in "TONE (DTMF)" mode makes an SMS call using outside (CO) lines 
set to "Pulse" or "Call Block" mode through system programming (
Dial Mode [401]), if the SMS 
centre number is longer than supported, for example 16 digits, the SMS call may not be completed. In 
this case, set the dialling mode of the SLT to "PULSE" mode using the switch.
Extension Jack No.
SMS Centre Number for 
Sending
SMS Centre Number for 
Receiving
SMS Sub-
address
Jack 01
89 P1112223333
1112224444
Jack 02
89 P1112223333
1112224444
Jack 03
89 P1112223333
1112224444
(Cont.) :
:
:
:
:
:
:
: