INSTALLATION 
 1085
 Aperture
Typical section showing 
ventilation requirements
Aperture   
 1085 H x 700 W x 580 D
 700
 
600
Above floor
level
Floor
 60
 +
_30
 +
_30
 +
_30
 +
_30
Aperture
32
32
 
 
• 
Support the oven in front of the aperture and make the electrical connection before 
installing. This will ensure enough cable length  for subsequent servicing. 
• 
Unscrew and remove the top and bottom trims to expose the fixing holes. 
• 
Secure the oven to the cabinet using suitable screws. ( Fasteners are not provided.) 
• 
Replace the top and bottom trims. 
 
ELECTRICAL INSTALLATION 
 
This appliance must be earthed and the manufacturer and the seller do not 
accept responsibility for any damage due to incorrect installation or 
electrical connection.” 
 
Earth leakage 
This appliance should not be connected through an earth leakage system.  
Refer to S.A.B.S. 0147. 
Connection to the power supply must be carried out by a licensed electrician, who will 
ensure that the oven is correctly connected and safely earthed. The rated current is printed 
on the serial number label attached to the oven bottom trim. 
The appliance must be connected to the mains through a double pole isolating switch 
which has a minimum clearance between the contacts of 3 mm. in both poles. 
A means for disconnection must be provided in the fixed wiring.