Installation Instructions
Before proceeding, turn off power to the circuit to which  
1. 
the oven will be connected at the circuit breaker or fuse 
box.
Position the oven directly in front of the cabinet cutout.
2. 
Feed the appliance conduit into the electrical junction 
3. 
box and attach it using a UL approved strain relief.
Depending upon local codes, utilize one of three meth-
4. 
ods to connect the appliance to the electrical power:
Connect to a four wire electrical system
Connect to a three wire electrical system, where 
local codes permit 
Connect to a three wire electrical system with 
external ground, according to local codes.
Connecting to a Four Wire Electrical 
System
Separate the wires coming out of the appliance conduit.
1. 
Connect the white wire from the appliance conduit to 
2. 
the white (neutral) supply wire in the junction box.
Connect the black wire from the appliance conduit to 
3. 
the black (L1) supply wire in the junction box.
Connect the red wire from the appliance conduit to the 
4. 
red (L2) supply wire in the junction box.
Connect the green wire from the appliance conduit to 
5. 
the green (ground) wire in the junction box.
Electrical Service Installation
 WARNING
Wire the oven only in compliance with local ordi-
nances.
If the electrical service provided does not meet 
the product specifications, do not proceed with the 
installation. Call a licensed electrician to install the 
required wiring.
To prevent an electric shock or fire hazard, turn off 
power to the circuit at the circuit breaker or fuse box 
prior to connecting the wiring to the oven.
Improper connection of the electrical wiring can 
cause an electric shock hazard and damage the 
appliance. Dacor is not responsible for damages 
resulting from improper installation.
Connect the ground terminal (or lead) on the appli-
ance to a grounded, metallic, permanent wiring sys-
tem or grounding conductor.
Do not use an extension cord with this appliance. 
Such use may result in fire, electric shock or other 
personal injury.
Do not install a fuse in the neutral or ground circuit. 
A fuse in the neutral or ground circuit may result in 
an electric shock hazard.
The appliance must be connected to the power sup-
ply with copper wire only. The use of aluminum wire 
may result in unsatisfactory connections.
Flexible armored or non-metallic, sheathed copper 
cable (with grounding wire) should be used to con-
nect the appliance to the junction box. An UL-listed 
connector must be used to directly connect the cable 
to the junction box.
 IMPORtANt
Make sure that the conduit is long enough to allow the 
oven to be pulled out for service without disconnecting it 
from power.
Conduit from 
appliance 
Cable from 
power supply 
Wire nut
(4 places)
Junction
box
RED 
RED 
GREEN 
GREEN 
WHITE 
WHITE 
BLACK 
BLACK 
4 Wire Junction Box Connection