Dacor MOH230 Benutzerhandbuch

Seite von 20
6
“C”
9 5/8” (244mm) 
Recommended 
(May be altered) 
1 ¾“ (45mm)
Clear to Top 
of Drawer for 
Heat Exhaust
“B” 
“A” 
4“ Typical Toe Kick (Shown) 
Recommended 
Electrical  
Location 
3/4” (19mm) 
Support Platform 
1“ (25mm) 
Clear to Top  
of Drawer for  
Heat Exhaust 
“C”
“A” 
“B” 
31 1/4” (794mm) 
Recommended 
(May be Altered) 
1 ¾“ (45mm) Min.
Clear to Top of
Door for Heat
Exhaust
4“ Typical Toe Kick (Shown) 
Recommended 
Electrical  
Location 
Alternate 
Electrical  
Location 
3/4” (19mm) 
Support Platform 
1“ (25mm) Min.
Clear to Top of
Door for Heat
Exhaust
Planning the Installation
Model 
Number
A
B
C
D
EO127
27 7/16”
(697mm)
25 1/2”
(648mm)
27”
(686mm)
56 1/2” 
(1435mm)
PO127
MOV127
MOH127
EO130
28 1/2”
(724mm)
30”
(762mm)
62 1/2” 
(1588mm)
PO130
MOV130
MOV130
EO227
50 9/16” 
(1284mm)
25 1/2”
(648mm)
27”
(686mm)
NA
PO227
MOV227
MOH227
EO230
28 1/2”
(724mm)
30”
(762mm)
PO230
MOV230
MOH230
Single Wall 
Oven Cutout
Double Wall 
Oven Cutout
Selecting the Location
Carefully check the location where the oven is to be 
installed. The oven should be placed for convenient 
access, but away from drafts that may be caused 
by doors, windows, and heating, ventilation and air 
conditioning outlets. 
Make certain that electrical power can be provided 
in the selected location. Be certain that proper 
clearance is provided for the oven door when it is in 
the open position.
Cabinet Cut-Out
Plan the installation so that all minimum clearances 
are met or exceeded. Cutout dimensions shown 
provide minimum clearances, unless otherwise 
noted. 
The specified minimum cabinet depth and width 
must be provided. The cabinet depth and width 
must completely enclose the recessed portion of 
the oven.
Cabinet cutout dimensions must be used as indi-
cated.