Dacor MOH Benutzerhandbuch
6
Planning the Installation
Selecting the Location
• Carefully check the location where the oven is to be
installed. The oven should be placed for convenient
access, but away from drafts that may be caused by
doors, windows, and heating, ventilation and air condi-
tioning outlets.
• Make certain that electrical power can be provided in
the selected location. Be certain that proper clearance
is provided for the oven door when it is in the open
position.
Cabinet Cutout
• Plan the installation so that all minimum clearances are
met or exceeded. Cutout dimensions shown provide
minimum clearances, unless otherwise noted.
• The specified minimum cabinet depth and width must
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
• Cabinet cutout dimensions must be used as indicated.
A
B
4“ typical toe kick (shown)
3/4” (1.9 cm)
support platform
Recommended
electrical
location
9 5/8” (24.4 cm)
recommended
(may be altered)
1 ¾“ (4.5 cm) min.
clear to top of
door for heat
exhaust
1“ (2.5 cm) min.
clear to
bottom of
door
C
C
A
B
4“ typical toe kick (shown)
Alternate
electrical
location
3/4” (1.9 cm)
support platform
Recommended
electrical
location
31 1/4” (79.4 cm)
recommended
(may be altered)
1 ¾“ (4.5 cm) min.
clear to top of
door for heat
exhaust
1“ (2.5 cm)
min. clear to
bottom
of door
Model
Number
A
B
C
EO127
27” 7/16”
(69.7 cm)
25 ½”
(64.8 cm)
27”
(68.6 cm)
56 ½”
(143.5 cm)
MOH127
MOV127
EO130
MOV127
EO130
28 ½”
(72.4 cm)
30”
(76.2 cm)
62 ½”
(158.8 cm)
MOH130
MOV130
EO227
MOV130
EO227
50 9/16”
(128.4 cm)
25 ½”
(64.8 cm)
27”
(68.6 cm)
NA
MOH227
MOV227
EO230
MOV227
EO230
28 ½”
(72.4 cm)
30”
(76.2 cm)
MOH230
MOV230
MOV230
Single Wall
Oven Cutout
Double Wall
Oven Cutout
Cutout tolerances: +1/16 (1.6 mm), -0, unless otherwise stated.