7) Remove the thermostat bulb attachment (plastic) of the upper unit from the thermostat 
extension bracket (stainless).
8) Carefully remove the thermostat bulb from the thermostat bulb attachment (plastic) of 
the upper unit.
9) Carefully route the thermostat bulb and capillary tubing of the upper unit through 
the bottom hole of the upper unit. Remove the bushing from the lower bin control 
thermostat assembly. Route the bulb and tubing through the hole in the assembly and 
down into the bin. Reattach the bushing.
10) Secure the lower bin control thermostat assembly in place with the thumbscrew.
11) Carefully insert the thermostat bulb back into the thermostat bulb attachment (plastic).
1) Secure the thermostat bulb attachment (plastic) of the upper unit to the thermostat bulb 
attachment (plastic) of the lower unit with the screws of the upper unit.
13) Insert the plug of the upper unit into the receptacle of the upper unit's bin control 
thermostat assembly until it locks in place.
14) Place the panels and baffle in position. 
Thermostat 
Capillary 
Tubing
Thermostat Extension Bracket 
(stainless) or "Z" Bracket (plastic) 
Depending on Bin
Thermostat Bulb Attachment 
Removed from Upper Unit
Thermostat Bulb 
Attachment of 
Lower Unit
Thermostat Bulb
Fig. 7