Hoshizaki KM-1301SWH/3 Benutzerhandbuch

Seite von 84
46
4. KM-1301SWH3 (water-cooled) 
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in 
bold 
should be used for reference only.
. We reserve the right to make changes in specifications and design without prior 
notice.
70/21
1333
605
1323
600
1246
565
80/27
1326
601
1311
594
1198
544
90/32
1323
600
1300
590
1201
545
lbs./day   kg./day
100/38
1286
584
1277
579
1110
503
70/21
80/27
90/32
watts
100/38
70/21
1414
5.35
1526
5.78
2036
7.71
80/27
1499
5.68
1673
6.33
2382
9.02
90/32
1526
5.78
1795
6.80
2431
9.20
gal./day    m
3
/day
100/38
1846
6.99
1944
7.36
3015
11.41
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
237
16.7
238
16.7
249
17.5
80/27
238
16.7
239
16.8
256
18.0
90/32
238
16.7
240
16.9
255
17.9
PSIG     kg/cm
2
G
100/38
244
17.1
244
17.1
269
18.9
70/21
50
3.5
50
3.5
52
3.7
80/27
50
3.5
49
3.5
53
3.7
90/32
50
3.5
49
3.4
52
3.7
PSIG     kg/cm
2
G
100/38
51
3.6
50
3.5
55
3.9
17,400 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,300 BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
119 gal./h  [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
       less than 10 PSIG
2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE
HEAD PRESSURE
3.5
3.0
3.8
2.2
2.4
4.0
31
31
32
HARVEST CYCLE TIME
1805
1824
1850
1860
32
33
34
35
1789
1791
1818
1840
1842
1770
1786
1791
WATER TEMP. (ºF/ºC)
AMBIENT TEMP. 
(ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC 
CONSUMPTION
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
31
31
32
2.3
4.5
3.1
3.8
3.0
30
33
ENG.F-011.1.0205