Hoshizaki KMS-1400MLH Benutzerhandbuch

Seite von 29
I. Startup
IMPORTANT
1. Electrical power must be on at the condensing unit for a minimum of 4 hours 
prior to startup to prevent compressor damage.
2. All parts are factory-adjusted. Improper adjustments may result in failure.
3. If the unit is turned off, wait for at least three minutes before restarting the 
icemaker to prevent damage to the compressor.
4. Do not operate the unit in the "WASH" position without water in the water 
tank. This will cause damage to the water pump seal.
1) Open the water supply line shut-off valve.
2) Remove the front panel.
3) Move the control switch on the control box to the "ICE" position.
4) Replace the front panel in its correct position.
5) Allow the water tank to fill with water and the icemaker to operate for a total of 10 
minutes.
6) Move the control switch to the "OFF" position, and drain the water tank by removing the 
front panel, front insulation panel, front frame, and suction hose. See Fig. 10.
7) Replace the removed parts in their correct positions.
8) Clean the dispenser unit/storage bin using a neutral cleaner. Rinse thoroughly after 
cleaning.
9) Move the control switch to the "ICE" position to start the automatic icemaking process.
10) Replace the front panel in its correct position.
Fig. 10
Thumbscrew
Front Frame
Suction Hose