Manitowoc Ice KH0178 Merkblatt

Seite von 1
 
 
KH0178 - IB0620/0820/1020 ON A CORNELIUS 
 24.50” WIDE ICE DISPENSER (ENDURO 175) 
                                                                        Installation Instructions 
 
1.  Set adapter on top of the dispenser.  Position the bin cover so that the front flange of the bin cover will lock under the 
front lip of the dispenser.  Adapter may have to be moved towards the back of the dispenser. 
2.  Using the slotted holes in the adapter as a template, drill four (4) 9/64” diameter holes at the bottom of the slots.  
NOTE:  Do not drill deeper than 1/4” past the sheet metal.  Use a drill stop! 
3.  Fasten adapter to dispenser using the four (4) #8 screws supplied with the adapter kit. 
4.  Set the ice machine on top of the adapter.  Align holes in ice machine front angle with the rivnuts on the adapter. 
5.  Secure the ice machine to the adapter with two (2) #8-32 screws supplied with the kit. 
6.  Set the front bin cover onto the dispenser.  The back flange of the bin cover will latch onto the adapter. 
7.  Rotate retaining arms into position, as shown for normal ice machine operation. 
 
Manitowoc Ice, Inc.                                                                                                                                                            
2110 South 26
th
 Street, P.O. Box 1720, Manitowoc, WI  54221-1720 USA                                                                                                   
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879                                                    8006743                    
Web Site - www.manitowocice.com                                                                                                                                         
      Rev. 06/17/03 
Bin Cover 
#8-32 Screw 
 2 Places 
Adapter 
LH Retaining Arm 
#8 Screw  
4 Places 
RH Retaining Arm 
Cornelius ED175 Dispenser