For Best Performance:
Do not install 2 elbows together.
Use no more than three 90° elbows.
If an elbow is used, install it as far away as possible from the 
hood’s vent motor exhaust opening.
Make sure there is a minimum of 24" (61 cm) of straight vent 
between the elbows if more than one elbow is used.
The length of vent system and number of elbows should be kept 
to a minimum to provide efficient performance.
Cold Weather Installations
An additional backdraft damper should be installed to minimize 
backward cold air flow and a nonmetallic thermal installed to 
minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal 
break.
Makeup Air
Local building codes may require the use of makeup air systems 
when using ventilation systems with greater than specified CFM 
of air movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in your 
area.
Venting Methods
This range hood is factory set for vented installations. Vent 
system can terminate through either the roof or wall. A 
6" (15.2 cm) round vent system must be used. The vent system 
length should not exceed 35 ft (10.7 m).
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
Example vent system
NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce 
performance.
Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances. Save 
Installation Instructions for electrical inspector’s use.
It is the customer’s responsibility to contact a qualified electrical 
installer, and to assure that the electrical installation is adequate 
and in conformance with National Electrical Code, ANSI/NFPA 70 
(latest edition), or CSA Standards C22.1-94, Canadian Electrical 
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local 
codes and ordinances.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is 
required.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure range 
hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused 
disconnect (or circuit breaker) box through flexible armored or 
nonmetallic sheathed copper cable.
Wire sizes (copper wire only) and connections must conform 
with the rating of the appliance as specified on the model/
serial rating plate.
Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.
¹⁄₂" (12.7 mm) UL listed or CSA approved strain relief must 
be provided at each end of the power supply cable (at the 
range hood and at the junction box).
Option 1 - Roof Venting
Option  2 - Wall Venting
A. 6" (15.2 cm) round roof 
venting
B. Roof cap
A. 6" (15.2 cm) round wall 
venting
B. Wall cap
Vent piece
6" (15.2 cm) round
45° elbow
2.5 ft (0.8 m) 
90° elbow
5.0 ft (1.5 m)
A
B
A
B
Maximum length
= 35 ft (10.7 m)
1- 90° elbow
= 5 ft (1.5 m)
8 ft (2.4 m) straight
= 8 ft (2.4 m)
1 - wall cap
= 0 ft (0 m)
System length
= 13 ft (3.9 m)
90˚ elbow
2 ft 
(0.6 m)
6 ft (1.8 m)
wall cap