Be sure to reset the Lamp counter after the lamp is replaced. When the Lamp counter is reset, the LAMP 
REPLACE indicator stops lighting and the Lamp replacement icon disappears.
Press the MENU button to display the On-Screen 
Menu. Use the Point 
7 8
 buttons to move the red 
frame pointer to the Setting Menu icon.
Use the Point 
ed
 buttons to move the red frame 
pointer to Lamp counter and then press the SELECT 
button. A dialog box appears showing the total 
accumulated time of the lamp usage and the reset 
option. Select Reset and the “Lamp replacement 
counter Reset?” appears. Select [Yes] to continue.
1
2
Another confirmation dialog box appears, select [Yes] 
to reset the Lamp counter.
3
This projector uses a high-pressure lamp which must be handled carefully and properly.  
Improper handling may result in accidents, injury, or create a fire hazard.
 Lamp life may differ from lamp to lamp and according to the environment of use. There is no guarantee 
of the same life for each lamp. Some lamps may fail or terminate their life in a shorter period of time 
than other similar lamps.
 If the projector indicates that the lamp should be replaced, i.e., if the LAMP REPLACE indicator lights 
up, replace the lamp with a new one IMMEDIATELY after the projector has cooled down.  
    (Follow carefully the instructions in the Lamp Replacement section of this manual.) Continuous use of 
the lamp with the LAMP REPLACE indicator lighted may increase the risk of lamp explosion.  
 A Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its 
lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in 
which the projector and lamp are being used.
IF A LAMP EXPLODES, THE FOLLOWING SAFETy PRECAUTIONS SHOULD BE TAKEN .
If  a  lamp  explodes,  disconnect  the  projector’s  AC  plug  from  the  AC  outlet  immediately.  Contact  an 
authorized  service  station  for  a  checkup  of  the  unit  and  replacement  of  the  lamp.  Additionally,  check 
carefully to ensure that there are no broken shards or pieces of glass around the projector or coming out 
from the cooling air circulation holes. Any broken shards found should be cleaned up carefully. No one 
should  check  the  inside  of  the  projector  except  those  who  are  authorized  trained  technicians  and  who 
are familiar with projector service. Inappropriate attempts to service the unit by anyone, especially those 
who are not appropriately trained to do so, may result in an accident or injury caused by pieces of broken 
glass.
          LAMP HANDLING PRECAUTIONS
Resetting the Lamp Counter
Note:
 • Do not reset the Lamp counter without implementing
lamp replacement. Be sure to reset the Lamp counter
only after replacing the lamp.
Select [Yes], 
then another 
confirmation 
box appears.
Select [Yes] again to reset 
the Lamp counter.
Select Reset and the “Lamp 
replacement counter Reset?” 
appears.
Lamp counter