NuTone QTXN110HFLT Benutzerhandbuch

Seite von 8
Page
MODEL   QTXN110HFLT
WARNING  
  
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1.  Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2.  Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power  from  being  switched  on  accidentally.  When  the  ser-
vice disconnecting means cannot be locked, securely fasten
a  prominent  warning  device,  such  as  a  tag,  to  the  service
panel.
3.  Installation  work  and  electrical  wiring  must  be  done  by  a
qualified  person(s)  in  accordance  with  all  applicable  codes
and  standards,  including  fire-rated  construction  codes  and
standards.
4.  Sufficient air is needed for proper combustion and exhausting
of  gases  through  the  flue  (chimney)  of  fuel  burning  equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5.  When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6.  Ducted fans must always be vented to the outdoors.
7.  Provide a separate 20 AMP circuit. Use 12 GA. power cable
of type which meets code.
8.  This unit must be grounded.
CAUTION  
1.  For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2.  This  product  is  designed  for  installation  in  ceilings  up  to  a
12/12 pitch. Duct connector must point up. DO NOT MOUNT
THIS PRODUCT IN A WALL.
3.  To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4.  Please read specification label on product for further informa-
tion and requirements.
QTXN SERIES HEATER / FAN / 
FLUORESCENT LIGHT /
NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS
CLEANING & MAINTENANCE
WARRANTY
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such 
products will be free from defects in materials or workmanship for a period of three 
years from the date of original purchase. THERE ARE NO OTHER WARRANTIES, 
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRAN-
TIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or replace, 
without charge, any product or part which is found to be defective under normal 
use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS 
AND TUBES. This warranty does not cover (a) normal maintenance and service or 
(b) any products or parts which have been subject to misuse, negligence, accident, 
improper maintenance or repair (other than by Broan-NuTone), faulty installation or 
installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the three-year period as specified 
for the express warranty. Some states do not allow limitation on how long an implied 
warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S  OBLIGATION  TO  REPAIR  OR  REPLACE, AT  BROAN-
NUTONE’S  OPTION,  SHALL  BE THE  PURCHASER’S  SOLE AND  EXCLUSIVE 
REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE 
FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF 
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do 
not allow the exclusion or limitation of incidental or consequential damages, so the 
above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which 
vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or 
telephone number stated below, (b) give the model number and part identification and 
(c) describe the nature of any defect in the product or part. At the time of requesting 
warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC    Hartford, Wisconsin    www.nutone.com    888-336-3948
Installer: Leave this manual with the homeowner.
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
Replace light bulbs with (2) 18-Watt 3500K (maximum), GU24
based fluorescent lamps and (1) 7-Watt night light bulb.
OPERATION
Use a 4-Function Control to operate the heater, fan, light, and
night light separately. See “Connect Wiring” for details.