Viking VIPR102 Benutzerhandbuch

Seite von 40
3
VIKING RANGE, LLC
Downdraft Ventilators
1.  The interior  down-
draft blower system is 
designed for use with 
3-1/4" x 10" duct-
work (can be transi-
tioned to 6" round). 
Three different dis-
charge directions are 
available with side-to-
side adjustment for 
accurate alignment of 
ductwork.
2.  For best perfor-
mance: Choose the 
ducting option which 
allows the shortest 
length of ductwork 
RIGHT
DISCHARGE
DOWN DISCHARGE
LEFT
DISCHARGE
PLAN THE DUCTWORK
Interior Blower Installation
Exterior Blower Installation
10" ROUND
DISCHARGE 
PLATE
1.  The exterior downdraft 
blower system is designed 
for use with 10" round 
ductwork.
2.  For best performance: 
Plan ducting which has the 
shortest length of ductwork 
and a minimum number of 
elbows. Check location of 
fl oor joists, wall studs, elec-
trical wiring or plumbing 
for possible interference. 
EQUALS 6 FT. OF 
STRAIGHT DUCT
10" ROUND
ELBOW
EQUALS 6 FT. OF 
STRAIGHT DUCT
6" ROUND 
ELBOW
EQUALS 8 FT. OF
STRAIGHT DUCT
3.  The system will operate most effi ciently when the ductwork 
does not exceed 40 feet of equivalent duct. The chart, above, 
shows equivalent feet of elbows and transitions. The number 
of feet of straight duct plus the equivalent feet of transitions 
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has 
been taken into consideration. Do not include them in this 
calculation.
3-1/4" X 10" TO 6" RD. 
TRANSITION
3-1/4" X 10"
90
O
 ELBOW
29   "
5
16
2   "
1
8
VIDV500
INTERNAL
BLOWER
5"
2"
1"
3   "
1
4
3   "
5
8
1
4
7   "
11
16
18"
FROM
COUNTERTOP
TO BOTTOM
OF AIR BOX
"
29   "
5
16
2   "
1
8
2"
1"
3   "
1
4
3   "
5
8
1
4
7   "
11
16
FROM
COUNTERTOP
TO BOTTOM
OF AIR BOX
"
3   "
3
16
1
4
"
13
1
4
"
13
1   "
9
16
10" ROUND
ELBOW
and a minimum number of elbows and transitions. Check 
location of fl oor joists, wall studs, electrical wiring or 
plumbing for possible interference. 
3.  The system will operate most effi ciently when the ductwork 
does not exceed 40 feet of equivalent duct. The illustration, 
above, shows equivalent feet of a 10" round elbow. The 
number of feet of straight duct plus the equivalent feet of 
elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has 
been taken into consideration. Do not include them in this 
calculation.
Interior Blower Installation
Exterior Blower Installation
TAKE MEASUREMENTS 
(CONTINUED)
EQUALS
2 FT. OF
STRAIGHT DUCT
SIDE VIEW
OF DOWNDRAFT
WITH
VIDV500
INTERIOR
BLOWER
SIDE VIEW
OF DOWNDRAFT
WITH
10" ROUND ELBOW
(for connection 
to VEDV900 or 
VEDV1200 Exterior 
Blower)
VIDV500
INTERIOR
BLOWER