CONNECT WIRING TO VIL1200 INLINE FAN
1.   The opposite end of this wiring will be connected to the 
rough-in plate in the next step.
2.  Remove wiring box cover from the inline fan.
3.   Attach  an  appropriate  UL  approved  cable  connector  to 
the wiring hole in the wiring box.
4.   Bring electrical wiring through the cable connector in the 
electrical box.
5.  Make electrical connections per the diagram shown below
6.  Attach wiring box cover.
CONNECT WIRING TO THE ROUGH-IN PLATE
1.   Run 115VAC electrical power cable from the service panel 
and from the inline fan to the rough-in plate part number 
PV300008.
2.   Remove appropriate knockouts from the range hood rough 
in box.
3.   Attach appropriate UL approved cable connectors to the 
wiring holes in the range hood rough-in box.
4.   Feed 6” of power cable through the cable connectors in 
the rough-in plate.
5.   Using the diagram below make all electrical connections 
to the rough-in plate.  
6.  Attach wiring box cover to rough-in  plate.
7.   Attach  rough-in  plate  to  the  studs  at  the  inside  top  of 
the  range  hood  with  the  (4)  #10-24  nuts  part  number 
PV300146 provided.
8.   Connect the plugin power cables of the rough-in  kit to 
the range hood.
3
�����
�����
�����
�����
���������
��������
���������
���������
������
�������
��
����
������������
115V