Viking F20470I EN Installationsanweisungen

Seite von 24
9
Dimensions & Specifications
8
(VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”)
(VWH 18”H. 27” Deep Wall Hoods 36”, 48”, & 60”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
Clearance Dimensions
(VWH 18”H. Wall Hoods)
NOTE: Optional duct cover sold separately.
VWH 18”H. Wall Hoods
Description
30”
36”
42”
48”
54”
60”
Duct cover width
29-7/8”
(75.9 cm)
35-7/8”
(91.1 cm)
41-7/8”
(106.4 cm)
47-7/8”
(121.6 cm)
53-7/8”
(136.8 cm)         
59-7/8”
(152.1 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm)
Number of lights
2
2
2
3
3
4
Number of filters
2
2
2
3
3
4
Heat lamps
1
1
1
2
2
2
Interior ventilator kits
VINV300/
600/1200
VINV300/
600/1200
VINV600/
1200
VINV1200*
VINV1200*
VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL900/1200
DIL900/1200
DIL900/1200
DIL1200
DIL1200
DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.9/5.9
4.9/5.9
11.5
11.5
11.5
11.5
Exterior—Maximum amps
8.7/6.0
8.7/6.0
8.7/6.0
8.5/9.2
8.5/9.2
8.9/9.2
In-Line—Maximum amps
6.0/7.9
6.0/7.9
6.0/7.9
10.3
10.3
10.7