1. Choose a position on the outside wall. Make sure that no
wall studs, pipes or wires run through the opening area.
2. From inside, mark and drill a guide hole centered
between wall studs.
PREPARE THE INSTALLATION
LOCATION
ROOF INSTALLATIONS
22"
2"
7"
29-1/2"
2"
WALL INSTALLATIONS
1. Locate the ventilator on the rear slope of the roof. Place
it in a location to minimize duct run. The location should
be free of obstacles (T.V. leads, electrical lines, etc.). If
the ventilator top is level with the roof peak, it will not be
seen from the street. Keep this approximate location in
mind as you work from within the attic.
2. Mark and drill a guide hole centered between roof
rafters.
2
3. From the outside, use the guide hole as a starting point
to lay out the installation:
A. Use a T-square to measure 9
13
/
16
" to the left of the
guide hole, then up 12
11
/
16
" to locate the top-left
corner of the layout.
B. Starting from the top-left corner, mark the rectan-
gular cutout (18" W x 20½" H) and remove only the
shingles in this area.
C. Mark an 11" diameter hole centered on the guide
hole. Cut this hole through the roof board(s).
D. Mark and cut a 1¼" diameter hole through the roof
board(s) where shown.
4. For flat roof installations, build a curb that will mount the
ventilator at a minimum pitch of 2/12. Discharge end of the
ventilator should be pointed away from prevailing winds.
PREPARE THE INSTALLATION
LOCATION
11" dia.
hole
20½"
11" dia.
hole
1"
Ø
Ø
9
11
/
16
"
20½"
Ø
Ø
15"
9
13
/
16
"
18"
12
11
/
16
"
1¼" dia. hole
1¼" dia. hole
Roof Rafter
Roof   Rafter
Roof Rafter
REMOVE SHINGLES
REMOVE SHINGLES
Roof   Rafter
Guide hole
(centered
between rafters)
Guide hole
(centered
between rafters)
12
11
/
16
"
18"
3. From the outside, use the guide hole as a starting point
to lay out the installation:
A. Use a T-square to measure 11
13
/
16
" to the left of the
guide hole, then up 14
11
/
16
" to locate the top-left
corner of the layout.
B. Starting from the top-left corner, mark the rectan-
gular cutout (22" W x 29½" H) and remove only the
siding in this area.
C. Mark an 11" diameter hole centered on the guide
hole. Cut this hole through the roof board(s).
D. Mark and cut a 1¼" diameter hole through the roof
board(s) where shown.