Mounting the hood body 
•  Before attaching the hood body, tighten the two screws Vr lo-
cated on the hood body mounting points. 
•  Hook the hood body onto the screws 12a.
•  Fully tighten the support screws 12a.
•  Adjust the screws Vr to level the hood body. 
12a
Vr
Connections 
DUCTED VERSION AIR EXHAUST SYSTEM 
When installing the ducted version, connect the hood to the 
chimney using either a flexible or rigid pipe ø 150 or 120mm, the 
choice of which is left to the installer. 
To install a ø 150 pipe 
•  To install the dumper 10
•  Fix the pipe in position using sufficient pipe clamps (not sup-
plied). 
To install a ø 120 pipe 
•  To install a ø 120 mm air exhaust connection, insert the redu-
cer flange 9 on the dumper 10.
•  Fix the pipe in position using sufficient pipe clamps (not sup-
plied). 
•  Remove any activated charcoal filters. 
9
ø 120
ø 150
10
10
RECIRCULATION VERSION AIR OUTLET 
•  Push fit connection 15 onto the hood body outlet.
•  Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
•  Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets. If this 
is not the case, adjust the position by either reversing the con-
nection extension pieces 14.1 and then reassemble as described 
previously. 
•   Ensure that the activated charcoal filters have been inserted. 
14.1
15