Vermont Casting BHDT36 Benutzerhandbuch

Seite von 34
- 9 -
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors. 
A =
Combustible 
  6"(152mm)
Noncombustible 
  2"(50mm)
B =
Combustible 
  6"(152mm)
Noncombustible 
  2"(50mm)
A
Balcony - 
with no side wall
G = 
Combustible&
Non-Combustible
  12"(305mm)
  
  
G
Balcony - 
with perpendicular side wall
H = 24"(610mm)
J = 20"(508mm)
      
H
J
B
Recessed Location
C = Maximum depth of 48"
       (1219mm) for recessed 
       location.
       
D = Minimum width for back wall 
       of a recessed location.
       Combustible 38"(965mm)
       Noncombustible 24"(610mm)
E = Clearance from corner in 
       recessed location.
       Combustible 6"(152mm)
       Noncombustible 2"(50mm)
C
D
C
E
V
V
Combustible &
Non-Combustible
V
V
V
Fig. 11
BEAD LOCATION
1" FROM CRIMPED END OF PIPE
1''
Screw Holes
Join pipes and secure joints with three (3) sheetmetal screws. (See Fig. 12)  Wipe off excess sealant.
Before joining elbows and pipes apply a bead of high temperature sealant to crimped end of elbow or pipe. (Fig.12)
Fig. 12
GENERAL INFORMATION ON ASSEMBLING
THE VENT PIPES WITH CRIMPED ENDS