Fisher & Paykel HS60CSW1 Benutzerhandbuch

Seite von 12
4
Installation instructions
Preparing the rangehood for installation
Ensure the overhead cabinets are built according to Fig.5 (below).
Before drilling any holes, check that the area 
behind the surface to be drilled is clear of any 
electrical cables or pipes etc. 
Recirculating
If the rangehood is to be installed as a 
recirculating hood, the knockouts shown in Fig.4 
should not be removed. For recirculation please 
purchase a charcoal filter (R103794C). 
Ducting
If the rangehood is to be installed as a ducted 
hood, remove the appropriate duct knockout.  
See Fig.4. 
1
  Remove Cover Tape ‘A’. See Fig.4.
2
  If 80 mm handle is not installed. Remove Front 
Fascia ‘B’ by undoing 3 screws on the fascia 
(see Fig.4). 
3
  Replace ‘B’ with Replacement Front Panel ‘C’ 
constructed of same or similar material as 
cupboard doors. See Fig.5 for height of panel.
Mounting the rangehood
The rangehood can be mounted in two ways, top or sides.
 
Before commencement, unpack the rangehood and check that it functions correctly.
Mounting to underside of cupboard
Fix rangehood to a shelf mounted at the right height in your wall units, by drilling 4 holes (see 
Fig.6) and fixing with 4 screws supplied.
Knockouts (remove for ducted only)
Fig.4 Preparing for install
Wall
Cupboard 
Door
For top ducting cut hole to suit size
Dimensions shown are for UNIDUCT
Drill 5 mm holes
Fig.6 Mounting to 
underside of cabinetry
Filtered air
Cooking fumes
Fig.5 Panel heights