Amana HRV-150D Benutzerhandbuch

Seite von 28
2
TABLE OF CONTENTS
TECHNICAL DATA
HRV(D) Series .................................................................................................. 3
HRV Series ...................................................................................................... 5
HRV-300D.................................................................................................... ...7
OPERATION............................................................................................................11
Modes Of Operation  ........................................................................................11
Optional Remote Controls ................................................................................ 12
Digital Multi-Function Controls w/recirculation.....................................................12
Digital Multi-Function Controls  .........................................................................13
INSTALLATION........................................................................................................14
Mounting the Unit  .......................................................................................... 14
Location & Ducting .......................................................................................... 15
Examples ....................................................................................................... 18
Air Flow Balancing  ......................................................................................... 22
MAINTENANCE ..................................................................................................... 24
TROUBLESHOOTING............................................................................................... 25
ELECTRICAL CONNECTIONS .................................................................................  26
Sizing (Example) for maximum airflow normally required.
HRVs are typically sized to ventilate the whole house at a minimum of 0.35 air changes per
hour. To calculate, simply take the square footage of the house (including basement) and multi-
ply by the height of the ceiling to get cubic volume. Then, divide by 60 and multiply by 0.35.
Example:
SQFT of House
1100
Basement
1100
Total SQFT
2200
Height of ceiling
x   8
Cubic volume
17600
/  60
Maximum airflow required (CFM)
293
x  0.35
103
* Always consult your local code for sizing requirements in your area.
Room classification
Number of rooms
CFM (L/s)
CFM Required
Master bedroom
x 20 cfm (10 l/s)
=
Basement
yes or no
=
Bedrooms
x 10 cfm  (5 l/s)
=
Living room
x 10 cfm  (5 l/s)
=
Others
x 10 cfm  (5 l/s)
=
Kitchen
x 10 cfm  (5 l/s)
=
Bathroom
x 10 cfm  (5 l/s)
=
Laundry room
x 10 cfm  (5 l/s)
=
Utility room
x 10 cfm  (5 l/s)
=
Total Ventilation Requirements (add last column )
=
if yes add 20 cfm / 10 l/s
if no = 0
1 cfm = 0.47189 l/s
1 l/s = 3.6 m
3
/hr