General Safety Information
Only qualified personnel should install this fan system. 
Personnel should have a clear understanding of these 
instructions and should be aware of general safety 
precautions. Improper installation can result in electric 
shock, possible injury due to coming in contact with 
moving parts, as well as other potential hazards. Other 
considerations may be required if high winds or seismic 
activity are present. If more information is needed, 
contact a licensed professional engineer before moving 
forward.
1.  Follow all local electrical and safety codes, as well as 
the National Electrical Code (NEC), the National Fire 
Protection Agency (NFPA), where applicable. Follow 
the Canadian Electrical Code (CEC) in Canada.
2.  The rotation of the wheel is critical. It must be free 
to rotate without striking or rubbing any stationary 
objects.
3.  Motor must be securely and adequately grounded.
4.  Do not spin fan wheel faster than maximum 
cataloged fan rpm. Adjustments to fan speed 
significantly effects motor load. If the fan RPM is 
changed, the motor current should be checked to 
make sure it is not exceeding the motor nameplate 
amps.
5.  Do not allow the power cable to kink or come in 
contact with oil, grease, hot surfaces or chemicals. 
Replace cord immediately if damaged.
6.  Verify that the power source is compatible with the 
equipment.
7.  Never open access doors to a duct while the fan is 
running.
DANGER
Always disconnect power before working on or near a 
fan. Lock and tag the disconnect switch or breaker to 
prevent accidental power up.
CAUTION
When servicing the fan, motor may be hot enough 
to cause pain or injury. Allow motor to cool before 
servicing.
CAUTION
Precaution should be taken in explosive atmospheres.
Vektor
®
-H
Vektor
®
-HS
Table of Contents
General Safety Information . . . . . . . . . . . . . . . . . . . . . . 1
  Receiving / Unpacking / Handling / Storage . . . . . . . 2
  Inspection and Maintenance during Storage . . . . . . . 2
 Removing 
from 
Storage 
. . . . . . . . . . . . . . . . . . . . . . . 3
General Information
  Unit and System Identification . . . . . . . . . . . . . . . . . . 3
 Pre-Installation 
Information 
. . . . . . . . . . . . . . . . . . . . 3
 Electrical 
Disconnects 
. . . . . . . . . . . . . . . . . . . . . . . . 3
  Moving Parts / Guards . . . . . . . . . . . . . . . . . . . . . . . . 3
  Air Pressure and Suction . . . . . . . . . . . . . . . . . . . . . . 3
Lifting Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Roof Curb and Mounting Details  . . . . . . . . . . . . . . . . . 4
Duct Installation - Bottom Inlet   . . . . . . . . . . . . . . . . . . 5
  
Side 
or 
End 
. . . . . . . . . . . . . . . . . . . 5
Stack Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
System Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Kitchen Roof Mounting Installation . . . . . . . . . . . . . . . . 6
Plenum Drainage Piping and Trap Detail  . . . . . . . . . . . 7
Electrical Connections  . . . . . . . . . . . . . . . . . . . . . . . . . 7
Variable Frequency Drive  . . . . . . . . . . . . . . . . . . . . . . . 8
Pre-Start-Up Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Maintenance 
  Belts / Fasteners and Set Screws . . . . . . . . . . . . . . . 9
 Motors  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
 Fan 
Shaft 
Bearings  
. . . . . . . . . . . . . . . . . . . . . . . . . . 9
 Bearing 
Relubication 
Schedule 
. . . . . . . . . . . . . . . . 10
  Vektor-HS Nozzle Bearings  . . . . . . . . . . . . . . . . . . . 10
 Damper 
Actuators  
. . . . . . . . . . . . . . . . . . . . . . . . . . 10
Parts List and Assembly . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance Log . . . . . . . . . . . . . . . . . . . . . . Backcover
Our Commitment . . . . . . . . . . . . . . . . . . . . . . Backcover
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble, 
install, operate or maintain the product described. Protect yourself and others by observing all safety 
information. Failure to comply with instructions could result in personal injury and/or property damage!
1
Vektor
®
-H and Vektor
®
-HS Laboratory Exhaust System
®
®
Document #469003
Model Vektor
®
-H and Vektor
®
-HS