Section 4   Verifying Operation 
1.  Turn on the emulator according to the procedures described in the H8/3664 E6000 Emulator 
User’s Manual (HS3664EPI61HE-U2 or HS3664EPI62HE-U2). 
2.  Verify the user system interface cable connections by accessing ports and checking the bus 
states of the pins.  If an error is detected, recheck the soldered IC socket and the location of pin 
1. 
3.  The emulator connected to this user system interface cable supports two kinds of clock 
sources: an emulator internal clock and an external clock on the user system, for the MCU 
clock and subclock.  For details, refer to the H8/3664 E6000 Emulator User’s Manual 
(HS3664EPI61HE-U2 or HS3664EPI62HE-U2). 
  To use the emulator internal clock 
Select the clock in the emulator station as the system clock (
φ
) and the subclock  
(
φ
w), by using the CLOCK command (emulator command). 
  To use the external clock on the user system as the system clock 
Select target clock t with the CLOCK command (emulator command).  Supply the external 
clock from the user system to the emulator by inputting the external clock from the OSC1 
tarminal on the cable head or connecting a crystal oscillator to the OSC1 and OSC2 
terminals. When a crystal oscillator is inserted into the OSC1 and OSC2 terminals for the 
system clock, the clock is generated by the oscillator circuits shown in figure 10.  To input 
an external clock from the user system, input clock pulses satisfying the specifications 
described in the MCU hardware manual into the OSC1 terminal.  The system clock (
φ
frequency is the same as the external clock frequency. 
  To use the external clock on the user system as the subclock 
Select target clock sub t with the CLOCK command (emulator command).  Supply the 
external clock from the user system to the emulator. Supply the external clock from the 
user system to the emulator by inputting the external clock from the X1 terminal on the 
cable head or connecting a crystal oscillator to the X1 and X2 terminals. When a crystal 
oscillator is inserted into the X1 and X2 terminals for the subclock, the clock is generated 
by the oscillator circuits shown in figure 10.  To input an external clock from the user 
system, input clock pulses satisfying the specifications described in the MCU hardware 
manual into the X1 terminal.  The subclock (