Magnetek Quattro DC Elevator Drive Benutzerhandbuch

Seite von 126
Appendix – Re-Assembly Procedure 
 
1
The connections are as follows: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 2 : Motor Side Module Position 
 
3.  Make the following electrical connections 
from the DC Bus Board in the Line Side 
Converter enclosure flowing straight 
across to the PWM DC Bus Board in the 
Motor Side Inverter enclosure.  See Figure 
 for more information.   
Use a 10mm hex socket with extension to 
connect a M6 nut, lock washer, and flat 
washer torqued to 7.9 N-m (70 in-lbs). 
Wire 
Number 
From DC 
Bus 
Board 
To PWM 
DC Bus 
Board 
Reference 
Name 
80 A17-E16 
A18-E22 +Bus 
80A A17-E15 
A18-E21  +Bus 
81 A17-E18 
A18-E24 -Bus 
81A A17-E17 
A18-E23  -Bus 
82 A17-E13 
A18-E19 
Neutral 
Table 1 : DC Bus Connections 
7
2
3
 
 
 
 
 
Motor 
Contactor  
Contactor 
Control Bd (A9)
Motor Field 
Controller 
(A24) 
Motor Side 
Inverter 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 2 : DC Bus Connections 
4.  Next, connect the wire harness JCC1 
coiled up on the right side of the Line Side 
Converter to the Contactor Control Board 
(A9).  Dress and secure all cables. 
Connect wire A9/TB1/1 to A9-TB1 pin 1 
and A9/TB1/4 to A9-TB1 pin 4 of the 
Contactor Control Board (A9) in the Motor 
Side Inverter.  Use a 1/8” x 4” flat 
screwdriver for the TB1 terminals.  Torque 
to 0.23-0.28 N-m (2-2.5 in-lbs). 
See Figure 2  for reference. 
 
JCC1
TB1-4 
TB1-1
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 2 : Contactor Control Board (A9) 
5.  Next, connect the wire harness A24J1 
coiled up on the right side of the Line Side 
Converter to J1 on the Field Control 
Module (A24) and A24J3 coiled up on the 
right side of the Line Side Converter to J3 
on the Field Control Module (A24).  J1 and 
J3 are located on the bottom right hand 
corner of the Field Supply Board.  Dress 
and secure all cables. 
Connect appropriately sized wires for the 
intended motor field current directly to the 
99