Appendix – Power Ratings 
 
Appendix 
Control Power Consumption 
 
Control Power (230VAC) consumption (max)* 
Drive Model Number 
kVA Watts 
Current 
(Amps) 
QDC125-xxxx-xxx 0.800 
700 
3.5 
QDC200-xxxx-xxx 1.250 
1100 
5.4 
QDC250-xxxx-xxx 1.250 
1100 
5.4 
 
*Note: Does not include the Elevator Brake 
 
Watts Loss 
 
Total System Power Loss (max)** 
Drive Model Number 
Watts BTU 
QDC125-xxxx-xxx 2150 
7342 
QDC200-xxxx-xxx 3350 
11440 
QDC250-xxxx-xxx 3550 
12123 
 
**Note: Includes both Control Power and 3-Phase Input Power Consumption 
 
Input / Output Ratings 
 
Input 
Output (rated max) 
Drive Model Number 
Voltage (V) 
Current (A)  Voltage (V) 
Current (A) 
Power (HP) 
QDC125-xxxx-xxx 
200 – 480 
80 
50 – 550 
125 
92 
QDC200-xxxx-xxx 
200 – 480 
130 
50 – 550 
200 
147 
QDC250-xxxx-xxx 
200 – 480 
180 
50 – 550 
250 
184 