Magnetek Quattro DC Elevator Drive Benutzerhandbuch

Seite von 126
Quattro DC Interconnections 
 
Contact 
Cfirm 
 
Encoder Connections 
The Quattro DC has connections for an 
incremental two-channel quadrature encoder.   
The Quattro DC requires the use of an encoder 
coupled to the motor shaft.  The encoder power 
can be either a +5VDC or +12VDC.   
The encoder pulses per revolution must be 
entered in the ENCODER PULSES parameter 
in the A1 submenu. 
Figure 3 shows the encoder connection 
terminals for non-single ended applications. 
17 
 
 
 
 
 
 
 
 
 
 
 
Figure 3: Encoder Connections 
Below shows the connection for the encoder 
option card, if they are configured to be single 
ended.  This configuration is not recommended, 
since, the Quattro DC encoder noise immunity 
circuitry is not in effect.  
 
 
 
 
 
 
 
 
 
 
 
 
Figure 4: Encoder Connections (Single-
Ended) 
 
Logic Inputs 
The Quattro DC’s nine programmable logic 
inputs are opto-isolated.  For more information 
on programming logic inputs, see Logic Inputs 
C2 submenu on page 61.
  The inputs become 
“true” by closing contacts or switches between 
the logic input terminal and voltage source 
common (or voltage source).  The inputs are 
sourcing inputs – nominally sitting at common 
and when the contacts or switches are closed, 
turning “true” at 24VDC. The voltage supply for 
the logic inputs is 24VDC. 
IMPORTANT 
/A 
TB1 
34 
35
 
36 
37 
38
 
39 
40 
41 
42 
/B 
/Z 
C_ISO 
+5V_ISO 
+12V_ISO 
Internal 24VDC power supply has a capacity of 
100 mA  
Note: Logic input 1 and 2 are reserved and pre-
wired for CONTACT CFIRM and CTR PWR 
SENSE respectively. 
The choices for the voltage source common (or 
voltage source) depend on if the user is using 
an external voltage supply or using the internal 
voltage supply.  See Figure 5 for internal supply 
example and Figure 6 for external supply 
example. 
 
 
 
 
 
 
 
A9JCC1-2 
A9JCC1-1 
A9TB1
11 
logic input 1 
logic input 2 
TB1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 5: Logic Input Diagram (Internal 
Supply) 
 
2
 
+24VDC isolated 
6
5
10 
43 
46 
44 
logic input common 
+24VDC iso. common 
+24VDC isolated 
+24VDC iso. common
5
 
logic input 3 
logic input 4 
logic input 5 
logic input 6 
logic input 7 
logic input 8 
logic input 9 
45 
+24VDC iso. common
CTR PWR Sense 
/A 
TB1 
34 
35
 
36 
37 
38
 
39 
40 
41 
42 
/B 
/Z 
C_ISO 
+5V_ISO 
+12V_ISO