Quattro DC Drive Operation and Feature Overview 
 
 
Status Indicator Lights 
Five status indicator lamps are provided on the 
front panel of the drive. 
READY
 – (GRN) Power is applied to the drive, 
there are no drive Faults and drive is 
ready to Run when requested.  The Run 
light will blink slowly when it is in DSPR 
(Drive Standby Power Reduction) Mode 
or not boosting, but three-phase power is 
applied. 
RUN
 – (GRN) Indicates that the motor 
contactor is closed and the drive is 
following applied references operating to 
control torque and speed 
PROGRAM INVALID
 – (RED) There is no 
valid program loaded. 
FAULT
 – (Red) A drive Fault exists that is 
preventing the drive from operating 
CURRENT LIMIT
 – (YEL) Motor current is 
being limited 
 
MONITOR / Adjust / Set-up Parameters: 
The values of all adjustments and set up 
parameters are stored locally in non-volatile 
drive memory.  Monitoring of live data status 
and modification of parameter values can be 
accomplished by sequences over the serial 
link or the Magnetek Operator.  They can both 
be attached at the same time to modify 
parameters or monitor drive operation.  
Detailed descriptions of all adjustments are 
located in later sections of this manual. 
 
 
 
 
 
 
 
 
READY
RUN
PROGRAM INVALID
FAULT
CURRENT LIMIT
 
 
 
 
 