Magnetek Quattro DC Elevator Drive Benutzerhandbuch

Seite von 126
Quattro DC Drive Parameters A1 
 
Detailed descriptions 
GAIN CHNG LEVEL 
(Gain Change Level ) 
Works in conjunction with HI/LO GAIN SRC in 
menu C0.  When the gain control source is set 
to internal, this parameter sets the speed 
reference level that controls the Hi/Lo gain 
switch.  The velocity regulator will use normal 
‘high gain’ when the reference speed is below 
this value, or ‘low gain’ settings when the 
speed reference is above this value. 
On some elevators when the speed response 
(gain) is set to high levels as required for good 
velocity tracking during acceleration, the 
resonant characteristics of the elevator ropes 
can cause car vibration while running at steady 
state speed.  To reduce this problem, the 
response (gain) of the speed regulator is 
effectively reduced to a lower value so that the 
resonant characteristics of the ropes are not 
continuously excited.  The High/Low gain 
switch modifies the sensitivity or response of 
the speed regulator via the gain reduce 
multiplier.   
The Gain Reduce Multiplier adjusts how much 
gain reduction will occur at higher speeds.  
The Gain Change Level (or external 
command) determines when the gain change 
will occur. 
High / low gain switching may be controlled 
either externally or internally.  The high / low 
gain source parameter (HI/LO GAIN SRC) in 
Configuration menu C0 allows for an external 
or automatic internal gain switch selection. 
The high/low gain switch may be controlled by 
either: 
0%
contract
speed
low gain 
mode 
Response of 
Speed Regulator
8.0 rad/sec 
 
10%
contract
speed
10% 
contract 
speed 
Response of 
Speed Regulator 
8.0 rad/sec 
HPV 900 Parameter Settings 
HI/LO GAIN SRC = internal 
GAIN REDUCE MULT = 80% 
GAIN CHNG LEVEL = 10 % 
RESPONSE = 10.0 rad/sec
 
Response of 
Speed Regulator 
10.0 rad/sec 
0% 
contract 
speed 
Response of 
Speed Regulator
10.0 rad/sec 
speed reference
100%
contract
speed
•  a logic input 
•  the serial channel    
•  the gain change level parameter (GAIN CHNG 
LEVEL), which defines a percentage of 
contract speed 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
High / Low Gain Example 
 
 
36