Quattro DC Utility U0 Menu 
 
Overspeed Test via Serial Channel 
 
•  Press the ENTER key again.  The sub 
menu LED will go out and data ent LED 
will turn on. 
 
Three different functions are included in this 
sub-menu. 
 
 
 
An overspeed test can be initiated by: 
•  an external logic input 
•  the serial channel 
•  directly from the digital operator 
Overspeed Test via Logic Input 
The external logic input can be used by:  
−  setting the Overspeed Test Source 
parameter to external tb1. 
−  defining a logic input terminal to ospd test src 
NOTE: This logic input requires a transition 
from false to true to be recognized - this 
prevents the overspeed function from being 
permanently enabled if left in the true state. 
The serial channel can be used by setting 
Overspeed Test Source (C1) parameter to 
serial. 
Overspeed Test via Operator 
The Digital Operator can also initiate the 
overspeed test by performing the following: 
•  While the Digital Operator display shows 
 
 
 
 
 
 
 
 
 
Press the ENTER key.  The sub-menu LED will 
turn on, and the Digital Operator will display: 
 
 
 
 
 
 
 
•  Press the up arrow or down arrow key and 
the display will change to: 
 
 
 
 
 
 
 
•  Press the ENTER key to begin the 
overspeed test. 
The value in the Overspeed Mult (A1) 
parameter is applied to the speed reference 
and the overspeed level, so that the elevator 
can be operated at greater than contract speed 
and not trip on an Overspeed Fault. 
When the Run command is remove after the 
overspeed test, overspeed test reverts back to 
its default of NO.  In order to run another 
overspeed test via the Digital Operator, the 
above steps must be repeated again. 
RESTORE DFLTS  
(Restore Parameter Defaults) 
Restore Drive Defaults 
This function resets all parameters to their 
default values except the parameters in the 
MOTOR A6 sub-menu. 
The following shows how to restore the drive 
defaults: 
 
 
 
 
 
 
 
 
Press the enter key 
 
 
 
 
 
 
 
Press the enter key again 
 
 
 
 
 
 
 
If the esc key is pressed, instead the reset 
action will be aborted 
RUN/FAULT 
SUB MENU 
DATA ENT 
RESTORE DRIVE  
U4      DEFAULTS? 
RUN/FAULT 
SUB MENU 
DATA ENT 
PRESS ENTER TO 
CONFIRM REQUEST 
RUN/FAULT 
SUB MENU 
DATA ENT 
DEFAULT RESTORED 
PUSH ANY KEY 
RUN/FAULT 
SUB MENU 
DATA ENT 
NO ACTION TAKEN 
PUSH ANY KEY 
RUN/FAULT 
SUB MENU 
DATA ENT 
UTILITY U0 
OVRSPEED TEST U4 
RUN/FAULT 
SUB MENU 
DATA ENT 
OVERSPEED TEST? 
U4            NO 
RUN/FAULT 
SUB MENU 
DATA ENT 
OVERSPEED TEST? 
U4            YES 
 
 
 
 
 
 
 
72