Magnetek Quattro DC Elevator Drive Benutzerhandbuch

Seite von 126
Quattro DC Fault F0 Menu 
 
 
Fault F0 menu 
The FAULTS F0 menu does not access 
settable parameters; instead, it provides a 
means of examining the drive’s active faults 
and the fault history.   
This menu also allows for clearing of active 
faults in order to get the drive ready to return to 
operation after a fault shutdown.
 
F0 Parameter 
Description 
Hidden 
Item 
Run 
lock
out 
F1 ACTIVE 
FAULTS 
 
 
 
 DISPLAY 
ACTIVE 
FAULTS? 
Contains a list of the active faults 
N N 
 RESET 
ACTIVE 
FAULTS? 
Allows for reset of active faults 
N N 
F2 FAULT 
HISTORY 
 
 
 
 DISPLAY 
FAULT 
HISTORY? 
Contains a list of up to the last sixteen faults 
N N 
 CLEAR 
FAULT 
HISTORY? 
Allows for the clearing of the fault history and fault counters 
N N 
 DISPLAY 
FAULT 
COUNTERS? 
Contains list of faults and the number of times they 
occurred 
N N 
 
Detailed Descriptions 
ACTIVE FAULTS  
(Active Faults)
   
This sub-menu contains a list of the active 
faults.  This sub-menu also allows the user to 
reset the active faults.   
Active Faults List 
The active fault list displays and records the 
active faults.  The faults will remain on the fault 
list until a fault reset is initiated. 
 
 
 
 
 
 
 
 
Press the enter key to enter the active fault list.  
Use the up and down arrow keys to scroll 
through the active faults. 
 
 
 
 
 
 
 
 
 
Resetting Active Faults 
The Reset Active Faults function allows the 
user to initiate a fault reset via the digital  
 
operator, regardless of the setting of the Fault 
Reset Source parameter (see User Switches 
C1 submenu on page 50
 
 
While the Digital Operator display shows: 
 
 
 
 
 
 
 
RUN/FAULT 
SUB MENU 
DATA ENT 
F1       FAULTS? 
 
Press the ENTER key.  The sub-menu LED 
will turn ON, and the Digital Operator will 
display: 
 
 
 
 
 
 
 
 
Press the ENTER key again to begin the fault 
reset procedure. The sub-menu LED will go 
out and the data ent LED will turn on. 
 
 
 
RUN/FAULT 
SUB MENU 
DATA ENT 
RESET ACTIVE 
F1       FAULTS? 
RUN/FAULT 
SUB MENU 
DATA ENT 
F1  CHARGE FAULT 
ACTIVE FAULTS 
 
 
 
DISPLAY ACTIVE 
RUN/FAULT 
SUB MENU 
DATA ENT 
FAULTS F0 
ACTIVE FAULTS F1 
RUN/FAULT 
SUB MENU 
DATA ENT 
RESET ISSUED 
PUSH ANY KEY 
76