TROUBLESHOOTING
9) If Pantry Room Damper Heater has trouble
Replace Damper
Is Damper Heater
normal?(about145ohm)
Is MAIN PCB connector
(CN91) inserted correctly?
Is the input voltage of
IC02 MICOM #42 normal?
Start
NO
YES
YES
YES
Bad contact of connector/ insert correctly
NO
1) Recheck the wire
2) Replace PCB MAIN
2) Replace PCB MAIN
NO
Normal(recheck)
Measure the resistance
between
①-② after
CN91 connector open 145ohm
± 7%
ERROR Code
☞ Checking method of Pantry Room Damper
resistance CN91#1(Black)
↔ #2(Brown)
**
∞Ω: Open(wire disconnection, heater
disconnection) trouble 0
Ω: Short trouble