DUCTING
A WhisperKOOL XLT ducting kit is available for purchase. The kit allows the warm air to exhaust to several places such 
as an attic, an adjacent room, or outside. The goal is to get the warm exhaust air away from the rear intake of the unit. 
The customer will need to purchase 8” flex ducting, along with any hangers needed to run the ducting outside. 
See page 29 for more information on purchasing a XLT ducting kit.
Using the Thermostat Controller
The in-line fan will turn on and push warm exhaust air away from the WhisperKOOL® unit, preventing 
the  unit  from  overheating. The  in-line  fan  is  capable  of  moving  warm  air  through  25  feet  of  8”  flex 
ducting (not included). The in-line fan can be set to automatically turn on at varying temperatures in 
order to conserve the most electricity.
Setting  the  Thermostat  Controller  to  its  lowest  setting  will  turn  the  fan  on  at  lower  temperatures 
(Around 70° F). Setting the Thermostat Controller to its highest setting will turn the fan on at higher 
temperatures (Around 100° F). If the unit isn’t cooling properly, setting the thermostat controller to a 
lower setting may fix the problem.
 S
TA
RT
ING
  
TEM
PE
RA
TU
RE
LO
HI
EXHAUST SIDE
Shown here: Ducting through ceiling
85°F Max 
Temperature
Plug
8” flex ducting
Drainline
XLT Ducting Kit