Fisher & Paykel RF195A Benutzerhandbuch

Seite von 96
92
System Specification and Performance Data Sheet 
Refrigerator Water Filter Cartridge Model UKF8001AXX
Specifications
Service Flow Rate (Maximum) 
0.78 GPM (2.9 L/min) 
Rated Service Life UKF8001AXX-750 (Maximum) 
750 gallons/2838 liters 
Maximum Operating Temperature 
100° F/38° C 
Minimum Pressure Requirement 
35 psi/241 kPA 
Minimum Operating Temperature 
33° F/1° C 
Maximum Operating Pressure 
120 psi/827 kPA
Performance Data
  *  Tested using a flow rate of 0.78 gpm; pressure of 60 psig;  
pH of 7.5 + 0.5; temp. of 68° + 5° F (20° + 3° C)
 **  Measurement in Particles /ml. Particles used were 0.5 - 1 microns
 *** NTU - Nephelometric Turbidity Units
General Use Conditions
Read this Performance Data Sheet and compare the 
capabilities of this unit with your actual water  
treatment needs.
DO NOT use this product where water is microbiologically 
unsafe or of unknown quality without adequate 
disinfection before or after the system. System certified for 
cyst reduction may be used on disinfected water that may 
contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK FOR 
COMPLIANCE WITH THE STATE AND LOCAL LAWS  
AND REGULATIONS.
Standard No. 42: Aesthetic Effects
 
Taste and Odor Reduction 
Chlorine Taste & Odor 
Mechanical Filtration Unit 
Particulate Reduction Class 1
Standard No. 53: Health Effects
 
Chemical Reduction Unit 
Lead, Atrazine, Lindane, Benzene, 
Carbofuran, p-Dichlorobenzene,  
Mercury & Toxaphene Reduction 
Mechanical Filtration Unit 
Cyst, Turbidity and Asbestos Reduction
Tested and certified by NSF International against ANSI/NSF Standards  
42 & 53 in  models UKF8001AXX-750 for the reduction of:
1000 Apollo Road 
Eagan, Minnesota 55121-2240 
651.450.4913 
EPA EST #10350-MN-005
100834/B
Standard No. 42: Aesthetic Effects
Parameter
USEPA  
MCL
Influent 
Challenge Concentration
Influent 
Average
Effluent
% Reduction
Min. Required 
Reduction
Average
Maximum
Average
Minimum
Chlorine
2.0 mg/L ± 10%
1.88 mg/L
<0.05136364 
mg/L
0.06 mg/L
>97.26%
96.84%
50%
T & O
Particulate**
at least 10,000 particles/ml 5,700,000 #/ml
30,583 #/ml
69,000 #/ml
99.52%
98.94%
85%
Standard No. 53: Health Effects
Parameter
USEPA  
MCL
Influent 
Challenge 
Concentration
Influent 
Average
Effluent
% Reduction
Min. Required 
Reduction
Average
Maximum
Average
Minimum
Turbidity
1 NTU**
11 ± 1 NTU***
10.7 NTU
0.31 NTU
.049 NTU
97.09%
95.20%
0.5 NTU
Cysts
99.5% Reduction
Minimum 50,000/L
166,500 #/L
< 1 #/L
< 1 #/L
> 99.99%
> 99.99%
>  99.95%
Asbestos
99% Reduction
10
7
 10
8
 fibers/L; fibers >10 
micrometers in length
155 MF/L
< 1 MF/L
< 1 MF/L
> 99.99%
> 99.99%
99%
Lead at pH 6.5
0.015 mg/L
0.15 mg/L + 10%
0.153 mg/L
< .001 mg/L
< .001 mg/L > 99.35%
> 99.29%
0.10 mg/L
Lead at pH 8.5
0.015 mg/L
0.15 mg/L + 10%
0.150 mg/L
< .001 mg/L
< .001 mg/L > 99.33%
> 99.29%
0.10 mg/L
Mercury at pH 6.5
0.002 mg/L
.006 mg/L ± 10%
0.006 mg/L
0.0003 mg/L
0.0005 mg/L
95.70%
90.91%
0.002 mg/L
Mercury at pH 8.5
0.002 mg/L
.006 mg/L ± 10%
0.006 mg/L
0.0008 mg/L
0.0015 mg/L
86.22%
75.93%
0.002 mg/L
Atrazine
0.003 mg/L
0.009 mg/L + 10%
0.009 mg/L
< 0.002 mg/L
0.002 mg/L
76.99%
75.31%
0.003 mg/L
Benzene
0.005 mg/L
0.015 mg/L ± 10%
0.014 mg/L
0.0006 mg/L
0.0011 mg/L
95.71%
92.14%
0.005 mg/L
Carbofuran
0.04 mg/L
0.08 mg/L ± 10%
0.081 mg/L
< 0.001 mg/L
< 0.001 mg/L
98.74%
98.46%
0.04 mg/L
p-Dichlorobenzene
0.075 mg/L
.225 mg/L ± 10%
0.208 mg/L
< 0.0005 mg/L < 0.0005 mg/L 99.76%
99.74%
0.075 mg/L
Lindane
0.0002 mg/L
0.002 mg/L + 10%
0.002 mg/L
0.000 mg/L
< 0.0001 mg/L 98.72%
96.50%
0.0002 mg/L
Toxaphene
0.003 mg/L
0.015 ± 10%
0.015 mg/L
< 0.001 mg/L
< 0.001 mg/L
92.97%
91.67%
0.003 mg/L
The retractable water filtration system uses a UKF8001AXX 
replacement cartridge. Timely replacement of filter cartridge 
is essential for performance satisfaction from this filtration 
system. Please refer to the applicable section of your User 
Guide for general operation, maintenance requirements and 
troubleshooting. Suggested retail price of replacement water 
filter is $39.99.
This system has been tested against ANSI/NSF 42 and 53 for 
reduction of the substance listed above. The concentration 
of the indicated substances in water entering the system was 
reduced to a concentration less than or equal to the permissible 
limit for water leaving the system, as specified in ANSI/NSF 42 
and 53.
Filter performance data sheet