4)  Loose strain relief by unscrewing the two 
strain relief's screws as in diagram. 
 
 
 
 
 
 
 
 
 
 
5)   Remove damaged supply cord set by taking 
off the 4 electrical connection screws (block 
L1, N, L2 and Ground screw, see diagram) 
6)   Insert the new supply cord set in the strain 
relief and lock it with two strain relief's 
screws in suitable position. 
7)   Fix well the ring terminals G, L1, N, L2 of the 
new supply cord set as shown in diagram 
with its 4 screws 
8)   Re‐install the back enclosure panel with 6 
screws 
9)  Slide the appliance back into its proper 
location 
10) Re‐connect the appliance to the electrical 
power. 
 
 
ELECTRICAL GROUNDING 
This appliance is equipped with a four‐prong plug 
for your protection against shock hazard and 
should be plugged directly into a properly 
grounded receptacle. Do not cut or remove the 
grounding prong from this plug.