INSTALLING THE ANTI‐TIP STABILlTY 
DEVICE 
The anti‐tip bracket shipped with the range must 
be properly secured to the rear wall as shown in 
the pircture below.  
The height of the bracket from the floor must be 
determined after the range legs have been 
adjusted to the desired height and after  the 
range has been leveled.  
Measure the distance from the floor to the 
bottom of the anti‐tip bracket receptacle on the 
back of the appliance. 
Position the two anti‐tip brackets on the wall at 
the desired height plus 1/8" (0.32 cm). The 
brackets must be placed at 2”5/16 (6,0 cm) from 
the side of the range. The distance between the 
two bracket is 25”1/4 (64,1 cm).  
Secure the brackets to the wall with appropriate 
hardware. 
Slide the range against the wall until the brackets 
are fully inserted into their receptacles on the 
back of the range. 
 
 
 
INSTALLATION REQUIREMENTS 
 
ELECTRICAL 
A properly‐grounded horizontally‐ mounted 
electrical receptacle should be installed no higher 
than 3" (7.6 cm) above the floor, no less than 2” 
(5 cm) and no more than 8” (20,3 cm) from the 
right side (facing product).  
Check all local code requirements. 
 
GAS 
An agency‐approved, properly‐sized manual shut‐
off valve should be installed no higher than 3" 
(7.6 cm) above the floor and no less than 2” (5 
cm) and no more than 8” (20.3 cm) from the left 
side (facing product).  
To connect gas between shut‐off valve and 
regulator, use agency‐approved, properly sized 
flexible or rigid pipe. Check all local code 
requirements.