Philips 240PW9EB/69 Benutzerhandbuch
240PW9 LCD
3
Technical Data
LPL Panel
Type NR.
Type NR.
: LPL LM240WU4-SLA1
Resolution
: 1920x1200 (WUXGA)
Outside dimensions
: 546.4 (H) x 352 (V) x 40.3 (D)
Pitch ( mm )
: 0.27
Color pixel arrangement
: RGB vertical stripes
Display surface
: Hard-coating(3H), anti-glare treatment of the
front polarizer
Color
depth
: 16.7 M colors
Backlight
: U-Shape 7 CCFL
Active area(WxH)
: 518.4(H) x 324(V)
View angle (CR>10): 178/178 (typ) for H/V
Contrast ratio
Contrast ratio
: 1000:1 (typ)
White luminance
: 400 (typ)
Color gamut
: 102%
Gate IC
: Magna
Source IC
: Magna
Response time
: 5 ms(typ)
Scanning frequencies
Hor.: 24 – 94 K Hz
Ver.: 48 - 85 Hz
Video dot rate:
Hor.: 24 – 94 K Hz
Ver.: 48 - 85 Hz
Video dot rate:
210MHz for VGA and 170 for DVI
Power input: 90-264 V AC, 50/60
± 2 Hz
Power consumption: < 90 W/ after 30mins, meet EPA tier 2 requirement
Functions:
(1)D-SUB analog R/G/B separate inputs, H/V sync separated, Composite
(H+V) TTL level, SOG sync
(2) DVI digital Panel Link TMDS inputs
Ambient temperature:
Functions:
(1)D-SUB analog R/G/B separate inputs, H/V sync separated, Composite
(H+V) TTL level, SOG sync
(2) DVI digital Panel Link TMDS inputs
Ambient temperature:
0
°C - 40°C
Power input connection
Power cord length
Power cord length
: 1.8 M
Power cord type
: 3 leads power cord with protective earth plug.
Power management
The monitor must comply with the Microsoft On Now specification, and
meet EPA requirements.
The monitor must comply with the Microsoft On Now specification, and
meet EPA requirements.
Mode
HSYNC
VSYNC
Video
Pwr-cons.
Indication
Rec.
time
Power
-On
On
On
active
90W typical
(After
30 mins)
Blue LED
--
Off
Off
Off
blanked
< 1 W
(<110V)
< 2 W
(<220V)
Blue LED
Blinking
3 sec on,
3sec off
< 3 s
DC Power
Off
N/A
< 1 W
LED Off
PIN No.
SIGNAL
1
Red
2
Green/ SOG
3
Blue
4
Sense (GND)
5
Cable Detect (GND)
6
Red GND
7
Green GND
8
Blue GND
9
DDC +3.3V or +5V
10
Logic GND
11
Sense (GND)
12
Bi-directional data
13
H/H+V sync
14
V-sync
15
Data clock
Pin No.
Description
1
T.M.D.S. data2-
2
T.M.D.S. data2+
3
T.M.D.S. data2 shield
4
No Connect
5
No Connect
6
DDC clock
7
DDC data
8
No Connect
9
T.M.D.S. data1-
10
T.M.D.S. data1+
11
T.M.D.S. data1 shield
12
No Connect
13
No Connect
14
+5V Power
15
Ground (for +5V) – Cable detect
16
Hot plug detect
17
T.M.D.S. data0-
18
T.M.D.S. data0+
19
T.M.D.S. data0 shield
20
No Connect
21
No Connect
22
T.M.D.S clock shield
23
T.M.D.S. clock+
24
T.M.D.S. clock-
Susceptibility of display to external environment
Operating
- Temperature
: 0 to 40
degree C
- Humidity
: 80% max
- Altitude
: 0-3658m
- Air pressure
: 600-1100 mBAR
Storage
- Temperature
: -20 to 60 degree C
- Humidity
: 95% max
- Altitude
: 0-12192m
- Air pressure
: 300-1100 mBAR
Note: recommend at 5 to 35
°C, Humidity less than 60 %