Hearth & Home Technologies GNBC30 Benutzerhandbuch

Seite von 28
34615 Rev G
4
12-02
NOVUS B-VENT INSTALLATION INSTRUCTIONS
1. U.S. AND CANADA CERTIFICATION
The Novus  B-Vent Gas Appliance has been tested in
accordance with the ANSI standard Z21.88-2000. In
Canada, the current CSA 2.33-2000, IR41, P4, and IR55
and have been LISTED by Underwriters Laboratories
Inc.  for  installation  as  described  in  this  manual. All
components are UL, AGA, CGA or CSA safety certified.
2. LOCAL CODES
This installation must conform with local codes. In the
absence of local codes comply with the National Fuel
Gas Code ANSI Z223.1-latest edition in the U.S.A., and
the CAN/CGA B149, Installation Codes in Canada.
For  assistance  during  installation  contact  your  local
dealer  or  contact  Heatilator  Technical  Services
Department, Hearth & Home Technologies, 1915 W.
Saunders Street, Mt. Pleasant, Iowa 52641, 1-800-843-
2848.
HEATILATOR® and NOVUS® are registered trademarks
of Hearth & Home Technologies
3. GLASS SPECIFICATIONS/CERTIFICATIONS
Heatilator gas appliances manufactured with tempered
glass may be installed in hazardous locations such as
bathtub  enclosures  as  defined  by  the  CPSC.  The
tempered glass has been tested and certified to the
requirements of ANSI Z97.1-1984 and CPSC 16 CFR
1202. (Safety Glazing Certification Council SGCC# 1595
and  1597. Architectural  Testing,  Inc.  Reports  02-
31919.01 and 02-31917.01.)
This  statement is in compliance with SPCS 16 CFR
Section 1201.5 “Certification and labeling requirements”
which refers to 15 USC 2063 stating “…Such certificate
shall  accompany  the  product  or  shall  otherwise  be
furnished  to  any  distributor  or  retailer  to  whom  the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
Note: 
Minimum and maximum clearances must be main-
tained at all times. Illustrations throughout these instruc-
tions reflect typical installations and are for design purposes
only. Actual installation may vary slightly due to individual
design preferences.
The illustrations and diagrams used throughout these in-
stallation instructions are not drawn to scale.
Tools and building supplies normally required for
installation:
Tools:
Building Supplies:
Saw
Wall-finishing  materials
Pliers
Framing material
Hammer
Surround
Phillips screwdriver
Caulking material
Tape measure
Plumb line
Level
Electric drill/bits
Square
Gloves
A. APPLICANCE SPECIFICATIONS
TYPICAL VERTICAL INSTALLATION
We strongly recommend that you DO NOT install B-
Vent Gas Appliances in strong negative air locations,
such as a basement or a public facility. Living rooms
with  cathedral  ceilings  could  be  susceptible  to  a
negative air situation, but such installations can be
overcome through raising the termination, depend-
ing  on  specific  installations.  This  appliance  uses
room air for normal operation and could have prob-
lems establishing a positive draft in a negative air
location. In lieu, we recommend a Direct Vent Gas
Appliance.