Thermador PCG48 Installationsanweisungen
English 4
Consider Make-Up Air:
•
Due to the high volume of ventilation air, a source of
outside replacement air is recommended. This is
particularly important for tightly sealed and insulated
homes.
outside replacement air is recommended. This is
particularly important for tightly sealed and insulated
homes.
•
A qualified heating and ventilating contractor should be
consulted.
consulted.
NOTE:
Ventilation hoods and blowers are designed for use with
single-wall ducting. Some local building codes may require
double-wall ducting. Before starting installation, consult
local building codes and agencies to insure that the
installation will meet local requirements.
Ventilation hoods and blowers are designed for use with
single-wall ducting. Some local building codes may require
double-wall ducting. Before starting installation, consult
local building codes and agencies to insure that the
installation will meet local requirements.
Cooktop
Width
Cooktop
Configuration
Minimum Recommended
Blower Capacity*
Ventilation Options
30”
4 burners
800 CFM
30” or 36” Pro Wall Hood
30” or 36” Custom Insert w/ optional blower
42” Island Hood w/ optional blower
30” or 36” Custom Insert w/ optional blower
42” Island Hood w/ optional blower
36”
4 burners with griddle
1000 CFM
36” or 42” Pro Wall Hood
36” Custom Insert w/ optional blower
42” or 48” Island Hood w/ optional blower
36” Custom Insert w/ optional blower
42” or 48” Island Hood w/ optional blower
6 burners
1100 CFM
48”
6 burners with griddle
1300 CFM
48”** or 54” Pro Wall Hood
48” Custom Insert w/ optional blower
54” Island Hood w/ optional blower
48” Custom Insert w/ optional blower
54” Island Hood w/ optional blower
Important Notes:
•
•
It is recommended that a Thermador Professional wall or island hood or custom insert is used with Thermador
Professional Cooktops.
Professional Cooktops.
•
Refer to www.Thermador.com for a complete selection of Professional Ventilation options, Blowers, and
Accessories.
Accessories.
•
* For high output gas cooktops (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is
recommended. If the cooktop has a griddle, add 200 CFM to the estimated blower capacity. Additional blower
capacity may be required for longer duct runs.
recommended. If the cooktop has a griddle, add 200 CFM to the estimated blower capacity. Additional blower
capacity may be required for longer duct runs.
•
For island applications, it is recommended to use a hood width that exceeds the width of the cooktop by 6”
(overlapping the cooktop by 3” on each end).
(overlapping the cooktop by 3” on each end).
•
**Not all 48” Pro Wall Hood models can accommodate a 1300 CFM blower option.
•
CFM = “cubic feet per minute” (standard blower capacity rating).