Southbend 4365A Benutzerhandbuch

Seite von 48
S
PECIFICATIONS
 
U
LTIMATE 
R
ESTAURANT 
R
ANGES
 
P
AGE 
4
 OF 
48 
O
WNER
M
ANUAL 
1190820
 
REV
 
3
 
(11/10) 
S
PECIFICATIONS
 
NOTICE 
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, 
Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to 
installation requirements for equipment. Therefore, installations should comply with all local codes. 
Southbend reserves the right to change specifications and product design without notice. Such revisions do not 
entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment. 
Southbend appliances are intended for commercial use only, not for household use. 
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, 
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1,
 or the Propane Installation Code CAN/CGA-
B149.2,
 as applicable, including: 
1.  The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). 
2.  The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 
kPa). 
 
C
LEARANCES
 
 WARNING 
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION 
There must be adequate clearance between ranges and combustible construction. Clearance must also be 
provided for servicing and for operation. 
Minimum Clearances for ranges with ovens: 
 
Standard Oven 
Convection Oven 
Double Oven Base 
Sides 
10 inches 
10 inches 
10 inches 
Back 
10 inches 
10 inches 
10 inches 
Floor 
zero 
zero 
zero 
Do NOT install charbroilers next to combustible materials.
 
Ranges are suitable for installation on combustible floors. 
Adequate clearance must be provided in the aisle and at the side and rear to allow the door to open sufficiently to 
permit the removal of the racks and for serviceability. 
On ranges with a convection-type oven, a minimum of 2 inches clearance must be allowed behind the motor and 
the rear non-combustible enclosure. Care must be taken to provide adequate air circulation to prevent the motor 
from overheating. 
 
E
LECTRICAL 
R
EQUIREMENTS
 
Ranges with a convection oven, electric oven, or infrared broiler require connection to a supply of electricity. The 
appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local 
codes, with the National Electric Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.  
An electrical diagram is located on the rear of the range. 
The range may be furnished with one or two power cords (one for each oven), each with a standard 115V, 60Hz, 
single-phase prong plug. Some ranges instead have terminal connections.  See the serial plate for maximum 
amperage requirements.