Southbend 448EE-3G/T Merkblatt

Seite von 2
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000  www.southbendnc.com
Models:
www.yatesgd.com  www.yatesgraphicdesign.com
 
 
448EE
 
448EE-2G/T     
 
448EE-3G/T
 
448EE-4G/T
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
.
Form 448EE-2G-3G-4G Rev 1 (04/07)
OPTIONS AND ACCESSORIES
10” Flue Riser
3/4” quick disconnect with flexible hose complies with
ANSI Z 21.69 (specify 3ft, 4ft, 5ft)
Casters-all swivel-front with locks
Hot Top plates - each plate replaces 2 Open burner section
Various salamander & cheesemelter mounts
available. (Please refer to the price list)
Auxillary griddle plates
Extra Oven Racks
Cabinet Base
NOTES:
1.  Optional -Hot Plate in lieu of 2
open top burners at 12,000 BTU/
burner (24,000 BTU total NAT or LP
2. T Prefix - Thermostat griddle
control with one (1) throttling-type
thermostat per burner. Temperature
range of 100
o
F to 450
o
F)
MISCELLANEOUS
- If using Flex-Hose, the I.D. should not be smaller than 3/4”     and
must comply with ANSI Z 21.69
- If casters are used with flex hose, a restraining device should
be used to eliminate undue strain on the flex hose
- For installation on combustible floors (with 6” high legs) and
adjacent to combustible walls, allow 6” clearance.
- Install under vented hood
- Check local codes for fire, installation and sanitary regulations.
NOTICE:
Southbend has a policy of continuous product research and
improvement.  We reserve the right to change specifications
and product design without notice.  Such revisions do not
entitle the buyer to corresponding changes, improvements,
additions or replacements for previously purchased
equipment.
Model:  448EE-2G/2T, 448EE-3G/3T, 448EE-4G/4T
Gas:
- 448EE-2G/2T Total BTU-NAT: 270,000; LP: 248,000
- 448EE-3G/3T Total BTU-NAT: 220,000; LP: 204,000
- 448EE-4G/4T Total BTU-NAT: 170,000; LP: 160,000
- One 3/4” male connection
- Required operating pressure:
- Natural Gas 4” W.C.
- Propane Gas 10” W.C.
- If using Flex-Hose, the I.D. should not be smaller than the I.D. of
the manifold of the unit to which it is being connected
- Check local codes for fire and sanitary regulations.
- If the unit is connected directly to the outside flue, and A.G.A
approved down draft diverter must be  installed at the flue outlet
of the oven
- Two speed motors are not available on Restaurant Range
Convection Ovens.
UTILITY INFORMATION
M
ODELS
E
XTERIOR
C
OOK
T
OP
D
OOR
O
PENING
O
VEN
B
OTTOM
3/4"
 
G
AS 
C
ONN
.
E
LECTRIC
Width
A
Depth
B
C
D
E
F
G
H
J
K
L
M
N
O
P
Q
R
448EE-2G/2T
448EE-3G/3T
448EE-4G/4T
48.63"
(1235)
34.00"
(864)
29.75"
(756)
31.00"
(787)
12.00"
(305)
2.75"
(70)
59.50"
(1511)
22.50"
(572)
31.00"
(787)
6.00"
(152)
37.00"
(940)
15.50"
(394)
13.00"
(330)
3.25"
(83)
30.25"
(768)
-
-
M
ODELS
B
URNERS 
(BTU
 
E
ACH 
NAT/LP)
O
VEN 
I
NTERIOR
C
RATE 
S
IZE
C
UBIC
V
OLUME
C
RATED
W
EIGHT
G
RIDDLE
O
PEN
O
VEN
W
IDTH
D
EPTH
H
EIGHT
W
IDTH
D
EPTH
H
EIGHT
448EE-2G/2T
3@(16K/16K)
4@(33K/30K)
2@(45K/40K)
19.50"
(495)
26.50"
(673)
14.00"
(356)
67.00"
(1702)
45.50"
(1158)
75.00"
(1905)
132.3 cu. ft
3.75 cu.m.
860 lbs.
390 kg.
448EE-3G/3T
4@(16K/16K)
2@(33K/30K)
2@(45K/40K)
448EE-4G/4T
5@(16K/16K)
-
2@(45K/40K)