A - Installation  instructions check and warnings  
 
 IMPORTANT: 
Please ensure that the cut out measurement, venting and wiring is as specified in the 
relevant section B of this manual. 
 
A licensed electrician with relevant qualifications must perform electrical work when installing or 
servicing the appliance. The supply cable and fuse rating must be suitable for the appliance. You 
must never repair or replace any part of the appliance unless specifically recommended in the 
operation manual. 
 
DO NOT LIFT COOKER BY THE FRONT DOOR AS THIS WILL DAMAGE THE OVEN 
 
Ventilation opening must not be covered or obstructed in any way.  
 
 VENTILATION 
The room containing this cooker should have an air supply in accordance with local regulations. 
 
All rooms require an open window, or equivalent and some rooms will require a 
permanent vent as well. 
For room areas up to 5 m
2
 an air vent of 100 cm
2
 is required. 
For room areas between 5 m
2
 and 100 cm
2
 an air vent of 50 cm
2
 is required. 
If the room is greater than 5 m
2
 and has a door that opens directly to the outside, then no 
air vent is required. 
If there are other fuel burning appliances in the same room local regulations should be 
consulted to determine the air vent requirements. 
 
DISCHARGE OF FUEL GASES  
  
 
 Cooking appliances must always discharge the flue
 gases into special hoods (fig.1-C), which must be 
 connected to chimneys, flue pipes or have direct 
 access to the outside. If it is not possible to connect 
 a hood, an electric fan can be fitted to a window or 
 a wall (fig.1-E), which must be turned on when the 
 cooker is on, as long as ventilation standards are 
 strictly adhered to.
Fig.1