Dacor ERD60 Merkblatt

Seite von 2
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.7
60” Wide,
Epicure
®
 Range
ERD60
1/2
Revised
06/25/08
27" (686mm) 
26" (660mm) 
28 1/2" (724mm) 
37” 
(940mm) 
to 
35 3/4" 
(908mm) 
Finished Side Panel 
24 3/8" (619mm) 
Rear of Control Panel/Oven Door 
Face of Control Panel/Oven Door 
Front Edge of Bullnose 
Handle 
6” (152mm) Backguard 
When Backguard and 
Side Panels are  
removed, the overall  
depth  decreases  
by 1" (25mm) 
Accessory 3” (76mm) Side Panels 
(Dacor Model No. AESP03) 
1 9/16" 
(40mm) 
ERD/EGR30, ERD60 ovERALL DImENsIoNs 
sIDE vIEW
NOTES:
1.   Utilities may be located in the lower left corner of 
the adjacent right cabinet. (Recommended)
2.  Contact your local building department to verify 
compliance with local code interpretation.
3.   Two electrical circuits and gas supplies required.
 waRNiNg
Observe all governing codes and ordinances during 
planning and installation.  Contact your local building 
department for further information.
This appliance must be installed in accordance with the 
accompanying installation instructions.
Dacor
®
Model No.
Dedicated Circuit*
Required
Total
Connected
Load
gas 
Type
Manifold
Pressure
Min. gas Supply
Pressure
ERD60
240 Vac, 4-wire, 60 Hz, 
30 Amp (Breaker) X2
4.1 kW
(21Amp) X2
Natural
5” Water Column
6” Water Column
ERD60LP
Liquid 
Propane
10” Water Column
11” Water Column
ELEctRIcAL AND GAs sUPPLy REqUIREmENts
*Two separate dedicated circuits are required, one for left and one for the right side of the range.
REAR vIEW
Power Cords
60" (1524mm) 
Factory installed 3/4” regulators 
(1/2” supply ok)
6" (152mm) 
Backguard