Dacor EGR30 Merkblatt

Seite von 2
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.1
30” Wide,
Epicure™ Range
EGR30
1/2
27" (686mm) 
26" (660mm)
28 1/2" (724mm) 
35 3/4"
(908mm)
to
37”
(940mm)
Finished Side Panel 
24 3/8" (619mm)
Rear of Control Panel/Oven Door
Face of Control Panel/Oven Door
Front Edge of Bullnose
Handle
6” (152mm) Backguard
When Backguard and 
Side Panels are  
removed, the overall  
depth  decreases  
by 1" (25mm) 
Accessory 3” (76mm) Side Panels
(Dacor Model No. AESP03)
1 9/16"
(40mm)
EGR30 
OvERALL DImENsIONs 
sIDE vIEW
NOTES:
1.   Utilities may be located in the lower left corner of 
the adjacent right cabinet. (Recommended)
2.  Contact your local building department to verify 
compliance with local code interpretation.
3.  Dacor rear top trim (part #26793; shipped with unit) 
must be used if backguard and side panels are 
removed.
4.  See the Combination Installation (CI) section if 
installing with a downdraft.
Revised
07/30/08
Dacor
®
Model No.
Electrical
Circuit
Required
Total
Connected
Load
Gas 
Type
Manifold
Pressure
Min. Gas Supply
Pressure
EGR30
120 Vac, 
60 Hz,
15 Amp
0.75 kW
(6Amp)
Natural
5” Water Column
6” Water Column
EGR30LP
Liquid 
Propane
10” Water Column
11” Water Column
 waRNING
Observe all governing codes and ordinances during 
planning and installation.  Contact your local building 
department for further information. 
This appliance must be installed in accordance with the 
accompanying installation instructions.
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.