Dacor DR30DH-C Benutzerhandbuch

Seite von 24
17
Installation Instructions
RED
RED
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
Connecting the Conduit to the House 
Electrical Junction Box
 
WARNING
•  Do not ground the appliance to a gas supply pipe or hot 
water pipe.
•  Do not turn on power to the appliance without it being 
permanently grounded.
•  A grounded cold water pipe must have metal continuity to 
electrical ground and must not be interrupted by insulating 
materials. Any insulating materials must be jumpered with a 
length of No. 4 copper wire securely clamped to bare metal 
at both ends.
NOTE: The power supply must be properly polarized. Reverse 
polarity will result in continuous sparking of the electrodes, even 
after flame ignition. If there is any doubt as to whether the power 
supply is properly polarized or grounded, have it checked by a 
licensed electrician.
1.  With the range positioned directly in front of the cabinet 
cutout, feed the appliance wires into the junction box. 
Depending upon local codes, utilize one of the three (3) 
methods shown to connect the appliance to the junction box.
2.  Connect the white wire from the appliance to the neutral 
(white) supply wire in the junction box.
3.  Connect the black wire from the appliance to the black (L1) 
power supply wire in the junction box.
4.  Connect the red wire from the appliance to the red (L2) power 
supply wire in the junction box.
5.  If using a 4-wire connection, connect the green wire to a 
grounded supply wire in the junction box or to a grounded 
cold water pipe. If connecting to a grounded cold water pipe:
◊  Use a separate copper grounding wire (No. 10 minimum) 
to connect to the cold water pipe by means of a clamp 
and an external grounding connector screw.
◊  If there are any materials that isolate the cold water pipe 
from ground, jumper it with a No. 4 copper wire, clamped 
on both ends.
6.  Replace the junction box cover.
Fasten clamp 
tightly on pipe
3-Wire Conduit-Junction Box 
Connection with External Ground
Separate No. 10 (minimum)
copper grounding wire
Meter or other 
insulating device
Bare metal
Metal
water pipe
Clamps
Insulated Pipe Jumper
No. 4
copper wire
RED
RED
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
Connection to 
power supply
Connection to 
power supply
Connection to 
power supply
Wire nut 
4 places
Junction box
4-Wire Conduit-Junction 
Box Connection
Connection to  
appliance
Connection to  
appliance
Connection to  
appliance
Wire nut 
3 places
Junction box
Junction box
3-Wire Conduit-Junction 
Box Connection