Planning the Installation
B
Gas 
inlet
A
C
7/8” (2.2 cm) dia. electrical 
connection hole in bottom*
D
Range electrical access, 
cover removed
Gas and Electrical Dimensions
Gas - Electrical Access Dimensions
A
B
C
D
4 3/4”  
(12.1 cm)
22 1/8”  
(56.2 cm)
8 3/4”  
(22.2 cm)
13 3/4” 
(34.9 cm)
* When using an appliance cord that is not factory 
installed, the hole size must be increased to 1 1/8”  
(2.9 cm) by removing the conduit bracket inside the 
range electrical access box (see page 14).
Gas Supply Requirements
Check your local building codes for the proper method of 
installation. In the absence of local codes, this appliance 
should be installed in accordance with the National Fuel Gas 
Code ANSI Z223.1.
Be certain that the appliance being installed is correct for 
the gas service provided (natural gas or LP gas). Also, if 
operating the range at an altitude above 4000 ft. (1219 m) 
make sure it is equipped for high altitude operation. Refer to 
the product data label and the table on the inside cover to 
determine the correct model.
See the table for gas supply pressure requirements.
The regulator inlet accommodates a 3/4” gas line. The range 
ships with a 1/2” to 3/4” adapter connected to the regulator.
Electrical and Gas Supply Connections
Gas Supply Specifications
Gas 
Type
Manifold 
Pressure* (WC)
Min. Gas Supply 
Pressure (WC)
Max. Input 
Pressure
Natural
5
6
1/2 psi
LP
10
11
1/2 psi
The ratings above are for reference only - refer to the product 
data label (see inside cover for location).