RL-854 Radio Control Unit
Type I, Style A
Operation
 2001 Siemens Airfield Solutions, Incorporated
96A0027L
Page 25
All rights reserved
Issued 5/01
See Figure 2.  Refer to Table 6.  All switches, pushbuttons, indication lights,
and fuses used in the operation of the RL-854 are located inside the cabinet.
Table 6.  Controls and Indicators
Part
Purpose
Controls
ON/OFF Switch S1
Controls primary AC power.
Fuse F1 (3/10 A, Slo-Blo)
Provides primary circuit protection.
Timer Test Fast Switch S3
Provides a fast check of the timer circuit, causing the timer to time-out in
approximately 20 seconds.
Timer Test Normal Switch S3
Timer takes 15 minutes to time-out.
Test Pushbutton S2
Tests receiver completely.  Depressing Test Pushbutton S2 produces the same type
signal that an aircraft transmitter produces.  It tests everything in the receiver except
the antenna.
Indicators
Power Light DS1
Indicates DC power is on.
Carrier Light DS2
Indicates the receiver is receiving a carrier in the proper frequency.
Timer Light DS3
Indicates the timer is powered and is in a 20-second or 15-minute cycle.
See Figure 7.  Startup procedures for the RL-854 Radio Control unit are
discussed below.
Controls and Indicators
Startup Procedures