ACR Electronics 9490 Benutzerhandbuch

Seite von 18
 
Y1-06-0209G  
14 
6.)  Record the  expiration date on  the HRU  expiration  label (K)  with an 
indelible marker. 
7.)  Slide  the  metal  mounting  rod  adapter  (L)  onto  top  of  HRU  unit. 
Place  the  HRU  release  rod  (C)  into  the  mounting  rod  adapter, 
aligning the holes.
 
 
8.)  With  pliers,  insert  slotted  spring  pin  (I)  into  the  aligned  holes, 
securing the three pieces together .(see Figure A).  
9.)  Place  the  HRU  assembly  with  the  expiration  calendar  facing  the 
bottom  mounting  plate  and  insert  rod  through  the  bottom mounting 
plate  hole  (Figure  A).  Insert  small  cotter  pin  (G)  through  the  small 
hole in the rod, securing the HRU to the bottom mounting plate. 
10.) Place the front cover onto the bottom mounting plate with the HRU 
release  rod  sticking  out  of  the  front  cover  hole.  Align  the  holes  on 
the  sides  of  the  front  cover  with  the  holes  in  the  metal  adapter 
brackets (J). (see Figure A). 
11.) Attach the front cover and bottom mounting plate using the 4 screws 
(F) as shown in Figure A. 
12.) Carefully  place  the  EPIRB  back  into  the  bracket  with  the  lanyard 
facing  toward  the  back  of  the  bracket  by  pushing  the  bracket 
ejector  spring  back  and  placing  the  beacon  into  the  bracket.  Close 
the  swing  arm  door  securely  to  hold  the  beacon  in  place. Lock  the 
swing  arm  door  in  place  with  the  door  pin.  Tighten  all  eight  (8) 
screws. 
13.) Place  HRU  expiration  label  (K)  on  the  outside  of  the  bracket  in  a 
visible location.  
 
 
Figure A