27
Main circuit error [E,15] details
A500
CHARGE
ALARM
 Left LED
 Right LED
There are two 7-segment LEDs on the 
right of the operation panel as shown on 
the right. The following fault details are 
indicated by the LED display.
 Brake unit 
cooling fin 
overheating
 Control 
board 
ambient 
temperature 
error
Output 
overcurrent
Cooling 
fan power 
supply 
error
Capacitor
overcurrent 
 Cooling fin 
overheat
Gate power 
supply 
error
   For example, if the display is 
   
 
, the output overcurrent , capacitor overcurrent and gate power supply 
    errors have occurred.
Name
Details
Brake unit cooling fin overheating
The inverter output will stop if the brake unit's cooling fin temperature rises above the
specified value.
Control board ambient temperature error
The inverter output will stop if the ambient temperature of the control board rises above
the specified value.
Output overcurrent
The inverter output will stop if the inverter's output current flows above the specified
value.
Cooling fan power supply error
The inverter output will stop if the cooling fan's power drops below the specified value.
Capacitor overcurrent
The inverter will stop if a current exceeding the specified value flows to the main circuit
smoothing capacitor.
Cooling fin overheat
The inverter output will stop if the cooling fin's temperature rises above the specified
value.
Gate power supply error
The inverter output will stop if the gate power supply voltage drops below the specified
value.