Intel SC5300 BRP Benutzerhandbuch

Seite von 94
Maintaining Your Server
 
52 
Intel® Server Chassis SC5300 User Guide 
Upgrading from a Fixed Power Supply to a Hot Swap 
Power Supply 
 WARNINGS 
Hazardous conditions, power supply
:  Hazardous voltage, current, 
and energy levels are present inside the power supply.  There are no 
user-serviceable parts inside it; servicing should be done by technically 
qualified personnel. 
 
1.  Disconnect power to the chassis after shutting down the server. 
2.  Remove the Primary Access Cover (see “Remove Primary Access Cover” in Chapter 2 for 
step-by-step instructions). 
3.  Remove the Air Ducts (see “Remove Air Ducts” in Chapter 2 for step-by-step instructions). 
4.  Disconnect all internal power cables from chassis components and server board. 
5.  Remove the eight screws holding the Fixed Power Supply shield in place (letter “A”). Remove 
the two screws holding the Fixed Power Supply inside the power supply bay (letter “B”). 
Remove the Fixed Power Supply (letter “C”). 
 
A
C
B
TP00694
 
Figure 61.  Removing Fixed Power Supply