Install and Cable the Cabinets 
Page 1-99
Connect Modem to Telephone Network 
1
8. For non-United States installations, set the remaining modem fields as 
shown in 
Table 1-20
.
9. Press 
Enter
 when the modem fields are properly administered.
Table 1-20.
Release 6 CMC Modem Fields 
Field
Description
Modem 
Connection
Default is none for Release 6 CMC. Set to external if a modem is used.
Modem Name
This field is 20 characters long and permits alphanumeric characters to 
provide a unique qualifier for a given modem.
RTS/CTS 
Enabled
Informs modem that communication with the data source UART is driven 
with RTS/CTS flow control. The default 6-character field name is &H1
Set the field name to \Q3 for Intel modems. This field is not 
case-sensitive.
Asynchronous
 Data Mode
Configures modem as an asynchronous device. This 8-character field 
name has a default value of &M0 (default) for Release 6csi. Set the field 
to &M0&Q0 for Intel modems. This field is not case-sensitive. 
DTE 
Auto-Data 
Speed
Adjusts the speed of the data source (DTE) UART to the outgoing 
(modem-to-modem) data rate. At maximum, this speed is 9600 baud. It 
is not desirable to have the serial data fill the modem buffer faster than 
the outgoing data rate, since data compression is disabled. The field 
name has a 6-character blank default value. The Paradyne products use 
S90=1 to enable this functionality while the Intel product uses \J1 to 
enable similar functionality. This field is not case-sensitive. 
Disable Data 
Compression
Turns off the default data compression algorithms used by most 
modems. The field has a blank field of 6 characters as default. The AT 
commands that control this are supported by similar commands; 
however, these commands do not operate in the same manner. The Intel 
modems require H0%C0 to disable V.42bis & MNP Class 5 data 
compression algorithms. The Paradyne products only use %C0 to 
disable both algorithms. This field is not case-sensitive.
Enable Error 
Control
Turns on the V.42 LAPM and MNP error control protocols. The field has a 
blank default of 6 characters. The Paradyne products use the command 
\N5 to enable V.42/MNP/Buffer error control while the Intel product uses 
\N3 to provide similar functionality. 
Misc. Init. 
Param
This field has a 20-character blank default and supports any initialization 
parameters not already specified. The AT commands specified in this 
field are always the last initialization parameters to be sent to the 
external modem. This field is not case-sensitive. 
Continued on next page