Install and Cable the Cabinets 
Page 1-91
Install Emergency Transfer Unit and Associated Telephones 
1
switches are used for each of the 5 circuits; switches 1 and 2 are used for 
circuit 1, switches 3 and 4 are used for circuit 2, and so forth. See 
Table 
1-16
For loop start, set the switches to the left. For ground start, set the 
switches to the right.
.
4. Connect a 25-pair cable between the male RJ21 25-pair connector on the 
808A and the yellow field on the MDF. 
 shows the pinouts.
5. Make cross-connections for each emergency trunk/emergency station 
pair. See 
6. On the trunk identification label at the bottom of the panel, record the trunk 
line, extension, and location for each circuit.
7. To each voice terminal designated as an emergency terminal, attach a 
label identifying it as such. The labels are provided with the unit.
8. Check the system for normal operation as follows:
a. Place the test switch (switch 12) in NORMAL OPERATION.
b. Ensure the power supply is providing -48 VDC at 80 mA maximum. 
The power LED  should be ON.
c. Check wiring connections.
d. Verify there is dial tone on all emergency transfer sets.
Table 1-16.
Trunk/Test Switches
Switch 
Number
Circuit 
Number
1
1
2
1
3
2
4
2
5
3
6
3
7
4
8
4
9
5
10
5
11
Not Used
12
Test Switch